5.
Verify that the Receiver button has learned the
Transmitter button by pressing the Transmitter
button again. The orange LED corresponding to
the learned button on the Receiver will flash. The
LEARN LED will also flash.
6.
Repeat steps 3 and 4 to learn additional
Transmitter buttons.
7.
Exit LEARN Mode. Press and release the LEARN
button.
Wiring Diagram
Relay Contact Ratings
Resistive
Voltage
Load
Up to 30 VDC
1 A
Up to 30 VAC
1 A
Up to 60 VDC
0.5 A
Up to 42.4 VAC
0.5 A
Operation
CCO 1
CCO 2
CCO 3
CCO 4
The green LEARN LED
turns OFF.
Third-party equipment
contact closure input.
Inductive
Load
0.2 A
0.1 A
Do not use
Do not use
Contact Closure
Outputs
Provide a contact
closure output for
as long as the but-
ton is pressed.
Programmable
Buttons
Button functions
are programmed
using the
HomeWorks
®
Utility.
LEARN Button
Used to enter
LEARN Mode.
LEARN Mode is
used when the
Receiver is learn-
ing Transmitter
buttons.
3