Descargar Imprimir esta página

BFT B EBA Manual De Instalación página 8

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 11
ENGLISH
These boards are compatible only with control panels using the
U-link protocol.
1) Fig.A. Serial connection of Control panels via B EBA RS 485 LINK board
This connection involves connecting a number of control panels and
can be used for the centralized operation of a number of automated
devices. That way, all the automated devices connected to the same
Address can be opened or closed with a single command received
from the Master control panel. The Address number allows you to
create groups of automated devices, each of which answers to its
own Master. Each Address can have only one Master. The Master
of Address 0 also controls the Masters and Slaves of the other
Addresses. Caution: the first control panel in the network must
be a Master. The maximum number of control panels that can be
connected in a single network is 32. See example in Fig.A.
WIRING REQUIRED FOR OPERATION:
The control panels are connected to each other with 3 wires relating
to the B EBA RS 485 LINK interface boards.Use twisted pair cabling
only. When using a telephone cable with more than one pair, it is
essential to use wires from the same pair (A-B). The length of the cable
between one module and the next must not be greater than 250 m.
SETTINGS REQUIRED FOR OPERATION:
Logic on control panels
First control
panel in
network: Master
Serial mode =1.
Address = "assigned
Master control
address number".
panels within
network
Serial mode=0.
Slave control
Address = "assigned address
panels
number".
Serial mode =0 (if slave)
Control panel
and 1 (if Master).
furthest
Address = "assigned
away
address number".
2) Fig.B/C. U-Link serial connection
The B EBA BLUE GATEWAY and B EBA RS 485 GATEWAY
modules allow you to connect a supervisor* to the local
network of compatible BFT U-link devices by means of
wireless Bluetooth technology for UNI-BLUE and by means
of RS-485 twisted pair cabling for UNI-SER. B EBA BLUE
GATEWAY and B EBA RS 485 GATEWAY must be connected
to the only local network device with the address 0. Each
network device must have a different address.
Using a U-link supervisor*, you can address each device in
the local U-link network and manage parameters, settings,
transmitters and diagnostics.
For information on the features of the supervisor and
available functions, refer to the relevant manual.
The network is made up of a device with a B EBA BLUE GATEWAY /
B EBA RS 485 GATEWAY module to which all the other devices are
connected using twisted pair cabling in a U-link serial connection.
The smallest possible network is made up of a single device
with the address 0 with a B EBA BLUE GATEWAY / B EBA RS 485
GATEWAY module.
WIRING REQUIRED FOR OPERATION:
The control panels are connected to each other with 3 wires relating
to the B EBA RS 485 LINK interface boards. Use twisted pair cabling
only. When using a telephone cable with more than one pair, it is
essential to use wires from the same pair (A-B). The length of the cable
between one module and the next must not be greater than 250 m.
Warning: if a control panel is simultaneously connected to:
- a B EBA RS 485 GATEWAY board and
- an external receiver
and simultaneous communications are required:
- from the PC to the B EBA RS 485 GATEWAY board via 485
adapter
- from the same PC to the external receiver board using U-Prog,
disconnect the external receiver from the 24V control pa-
nel power supply (Fig. E).
SETTINGS REQUIRED FOR OPERATION:
First control panel in
network with B EBA BLUE
GATEWAY
First control panel in
network with B EBA RS 485
GATEWAY module
8 - B EBA RS 485 LINK / B EBA BLUE GATEWAY / B EBA RS 485 GATEWAY
INSTALLATION MANUAL
Dip switch settings on B
EBA RS 485 LINK
DIP1=ON
DIP2=ON
DIP3=ON
DIP4=ON
DIP1=OFF
DIP2=OFF
DIP3=OFF
DIP4=OFF
DIP1=OFF
DIP2=OFF
DIP3=OFF
DIP4=OFF
DIP1=OFF
DIP2=OFF
DIP3=ON
DIP4=ON
Dip switch
Logic on control panels
settings
Serial mode = 0.
DIP1=ON
Address = 0.
DIP2=ON
DIP3=ON
DIP4=ON
Control panels with mo-
dule B EBA RS 485 LINK
Control panel furthest
away with B EBA RS
485 LINK
3) Fig.D. Serial connection for Opposite leaves.
This connection involves connecting two control panels for
the centralized control of two opposite barriers/gates.
In this case, the Master control panel will simultaneously
control the closing and opening of the Slave control panel.
WIRING REQUIRED FOR OPERATION:
- The Master control panel and Slave control panel are connected
to each other with 3 wires relating to the B EBA RS 485 LINK
interface boards. Use twisted pair cabling only. When using a
telephone cable with more than one pair, it is essential to use
wires from the same pair (A-B). The length of the cable between
one module and the next must not be greater than 250 m.
- All activation commands, as well as remote commands,
must refer to the Master board;
- All photocells (tested or otherwise) must be connected to
the Master;
- The safety edges (tested or otherwise) of the Master leaf
must be connected to the Master control panel;
- The safety edges (tested or otherwise) of the Slave leaf
must be connected to the Slave control panel.
SETTINGS REQUIRED FOR OPERATION:
- On the Master control panel, logic must be set as follows:
Serial mode = 3 and Address = 0
- On the B EBA RS 485 LINK board connected to the Master
control panel, all Dip switches must be set to ON
- On the Slave control panel, logic must be set as follows:
Serial mode = 2 and Address = 0
- On the B EBA RS 485 LINK board connected to the Slave
control panel, Dip switches 1 and 2 must be set to OFF and
Dip switches 3 and 4 set to ON
SETTINGS REQUIRED FOR OPERATION:
Logic on control
panels
M aster
Serial mode=3.
control
Address = 0
panel
Slave
Serial mode=2.
control
Address = 0.
panel
SPECIFICATIONS
Operating temperature range
Max. Bluetooth connection distance:
Between B EBA BLUE GATEWAY and
wireless programmer
Max. connection distance with cable:
Between B EBA BLUE GATEWAY/B
EBA RS 485 GATEWAY and B EBA RS
485 LINK
- Between B EBA RS 485 LINK and
B EBA RS 485 LINK
Max. network length
Max. N° of devices on 485 network
B EBA BLUE GATEWAY band
B EBA BLUE GATEWAY power
Dimensions
* Supervisor means either a palmtop programmer or
control software.
1
*
the max. network length can be extended using an RS
485 repeater.
2
*
the number of devices can be increased to 128 using an
RS 485 repeater.
DIP1=OFF
DIP2=OFF
Serial mode =0.
DIP3=OFF
Address = from 1 to 127
DIP4=OFF
(each control panel must
DIP1=OFF
have a different address
DIP2=OFF
from the others).
DIP3=ON
DIP4=ON
Dip switch settings
on B EBA RS 485 LINK
DIP1=ON
DIP2=ON
DIP3=ON
DIP4=ON
DIP1=OFF
DIP2=OFF
DIP3=ON
DIP4=ON
-20°/+50°c
20 m
250 m
1
500 m*
2
32*
2400 - 2483,5 MHz
Max average
30mW EIRP
42 x 29 mm (HxL)

Publicidad

loading