Joannes VENUS BA MS 24 Instrucciones De Uso, Instalación Y Mantenimiento página 25

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

VENUS BA MS 24- 34
Contents Description
Range
Pump deactivation tempera-
ture during Post-Circulation
0-100°C
(b02=1)
Pump deactivation tempera-
ture during Post-Circulation
0-100°C
(b02=2)
P10
Pump deactivation tempera-
ture during Post-Circulation
0-100°C
(b02=3)
Pump deactivation tempera-
ture during Post-Circulation
0-100°C
(b02=4)
Pump activation hysteresis
temperature during Post-Cir-
0-100°C
culation (b02=1)
Pump activation hysteresis
temperature during Post-Cir-
0-100°C
culation (b02=2)
P11
Pump activation hysteresis
temperature during Post-Cir-
0-100°C
culation (b02=3)
Pump activation hysteresis
temperature during Post-Cir-
0-100°C
culation (b02=4)
P12
Heating user max. set point
20-90°C
P13
Max. output in heating
0-100%
0=Fixed
1=Linked to set point
Burner shutdown in hot water
2=Solar (5)
production (b02=1)
3=Solar (10)
4=Solar (20)
Legionella protection (b02=2) 0-7=Activation days
P14
Burner shutdown in DHW
0=Fixed
(b02=3)
1=Linked to set point
2=Solar (5)
3=Solar (10)
4=Solar (20)
Legionella protection (b02=4) 0-7=Activation days
Comfort activation tempera-
0-50°C
ture (b02=1)
Hot water tank hysteresis
0-60°C
(b02=2)
P15
Comfort activation tempera-
0-80°C
ture (b02=3)
Hot water tank hysteresis
0-60°C
(b02=4)
Not used (b02=1)
Do not modify
Primary set point (b02=2)
70-85°C
P16
Comfort deactivation hystere-
0-20°C
sis (b02=3)
Primary set point (b02=4)
70-85°C
P17
DHW standby time (b02=1)
30-255seconds
No effect on adjustment
30-255seconds
(b02=2)
DHW standby time (b02=3)
30-255seconds
No effect on adjustment
30-255seconds
(b02=4)
P18
DHW user max. set point
40-70°C
(b02=1)
DHW user max. set point
40-70°C
(b02=2)
DHW user max. set point
40-70°C
(b02=3)
DHW user max. set point
40-70°C
(b02=4)
P19
DHW pump Post-Circulation
0-255seconds
(b02=1)
DHW pump Post-Circulation
0-255seconds
(b02=2)
DHW pump Post-Circulation
0-255seconds
(b02=3)
DHW pump Post-Circulation
0-255seconds
(b02=4)
P20
Max. output in DHW
0-100%
VENUS BA
VENUS BA
Default
MS 24
MS 34
50°C
20°C
33°C
33°C
33°C
20°C
10°C
5°C
47°C
47°C
47°C
5°C
80°C
80°C
80°C
80%
80%
80%
0=Fixed
0=No prot.
0=Fixed
0=Fixed
0=Fixed
0=No prot.
40°C
2°C
40°C
40°C
40°C
2°C
7
80°C
20°C
20°C
20°C
80°C
120seconds
120seconds
120seconds
120seconds
120seconds
120seconds
55°C
65°C
55°C
55°C
55°C
65°C
0seconds
30seconds
30seconds
30seconds
30seconds
30seconds
100%
100%
100%
cod. 3541I710 - Rev. 00 - 06/2016
Contents Description
Range
P21
Comfort1 standby time
0-100minutes
(b02=1)
Not implemented (b02=2)
Not implemented (b02=3)
Not implemented (b02=4)
P22
Comfort2 standby time
0-100minutes
(b02=1)
Not implemented (b02=2)
Not implemented (b02=3)
Not implemented (b02=4)
P23
Fan frequency in standby
0-70Hz
mode
P24
Post-Ventilation
0-120seconds
P25
Modulating pump adjustment
0-60°C
temperature (b02=1)
Modulating pump adjustment
0-60°C
temperature (b02=2)
Modulating pump adjustment
0-60°C
temperature (b02=3)
Modulating pump adjustment
0-60°C
temperature (b02=4)
P26
Primary exchanger protec-
0-150°C
tion temperature (b02=1)
Primary exchanger protec-
0-150°C
tion temperature (b02=2)
Primary exchanger protec-
0-150°C
tion temperature (b02=3)
Primary exchanger protec-
0-150°C
tion temperature (b02=4)
P27
System min. pressure value 0-8 bar/10
P28
System nominal pressure
5-20bar/10
value
P29
Exchanger protection inter-
0=No F43
vention (b02=1)
1-15=1-15°C/second
Not implemented (b02=2)
Exchanger protection inter-
0=No F43
vention (b02=3)
1-15=1-15°C/second
Not implemented (b02=4)
P30
Heating hysteresis after igni-
60-30°C
tion
P31
Timer for heating hysteresis
60-180seconds
after ignition
Notes:
1.
Parameters with more than one description vary their function and/or range in rela-
tion to the setting of the parameter given in brackets.
2.
Parameters with more than one description are reset to the default value if the pa-
rameter given in brackets is modified.
3.
The Maximum Heating Power parameter can also be modified in Test Mode.
Press the Reset button to return to the Service Menu. Press the Reset button for 20 sec-
onds to exit the card Service Menu, or exiting occurs automatically after 15 minutes.
VENUS BA
VENUS BA
Default
MS 24
MS 34
20minutes
--
--
--
--
--
--
--
42minutes
--
--
--
--
--
--
--
0Hz
0Hz
0Hz
30seconds
30seconds
30seconds
18°C
18°C
18°C
18°C
18°C
18°C
35°C
150°C
35°C
150°C
150°C
35°C
4 bar/10
4 bar/10
4 bar/10
7 bar/10
7 bar/10
7 bar/10
10°C/second
--
--
10°C/second
10°C/second
10°C/second
--
--
10°C
10°C
10°C
60seconds
60seconds
60seconds
EN
--
--
25