ORIGINAL DUST EXTRACTION UNIT INSTRUCTION MANUAL
Part Numbers: 64396, 64397, 64398, 64400, 64401, 64402, 64404, 64405,
64406, 64408, 64409 & 64410
Extraction unit for wet and dry substances
Switch
d operation for Standard units, Models:
2
64396, 64397, 64398, 64404, 64405 & 64406
The extraction output can be variably adjusted using the rotating switch
Pre-selection switch
64400, 64401, 64402, 64408, 64409 & 64410
It is important to select the correct setting for switch
being used. The extraction is not otherwise adjusted.
Hose Diameter
35 mm
27 mm
21 mm
Warning!
To reduce the risk associated with mechanical impact, high pressure and/or
improper handling:
Do not modify the connectors (
of the functional plate). Changing this may lead to unsafe conditions. If using different connector
systems please contact your 3M distributor.
To reduce the risks associated with fire and/or explosion:
Do not use the dust extractor in an area of potentially explosive atmosphere.
Use is not permitted in areas of explosive atmosphere or combustible dust
marked as zones 22, 2 and/or 1.
230V/110V power outlet
230V/110V power outlet on unit shall be marked by a label:
for 230 V unit : Maximum output:10 A / 2,4 kW
for 110 V unit : Maximum output:5 A / 550 W
d operation for units of the class "M", Models:
2
Switch 2d setting
e air in connector and
2
d according to the hose diameter
2
35
27
21
f air out connector - see also drawing
2
d.
2
min. Extraction
70 m³/h
40 m³/h
20 m³/h