other appliances generated by other than an electrical source.
Before proceeding with the assembly operations, remove the
anti-grease filter(s) (Fig.16) so that the unit is easier to handle.
- In the case of assembly of the appliance in the suction version
prepare the hole for evacuation of the air.
• We recommend the use of an air exhaust tube which has the
same diameter as the air exhaust outlet hole. If a pipe with a
smaller diameter is used, the efficiency of the product may be
reduced and its operation may become noisier.
• Hood assembly:
- Remove the structure from the packaging and remove the 2
screws A to separate the upper part from the lower part (Fig.2).
- Position hole template on the ceiling paying attention that
the arrow is positioned on the same side as the appliance
controls (Fig.3). Make 4, Ø8 holes in the ceiling and drive in 3
screws without completely tightening them. Pay attention not
to insert the screw into the hole marked with an X on the hole
template (the screws and expansion plugs must be suitable
for the type of wall).
- Take the upper part of the structure B (Fig.4) and insert the
3 slots onto the 3 screws that are not completely tightened.
Rotate slightly to fit (Fig.4). Drive in the fourth screw X and
tighten the remaining 3 to allow definitive blocking of the
upper part of structure B.
- Take the lower part of the telescopic structure C and insert it
into the upper structure B (Fig.5). Adjust the height by referring
to the amounts indicated in (Fig.15) and block it using the 8
screws G that are supplied (Fig.6).
• S uction version: fix the flexible pipe to the prepared air
evacuation hole (Fig.7).
• F iltering version: we have two different types of Kit, one
with extractable carbon filters (Fig.17) and the other one with
re-usable carbon filters (washable) (Fig.18).
- Fix the flexible pipe to the deflector M and fix screw I as
indicated in Fig.8, the active carbon filters must be applied to
the suction unit positioned inside the hood (Fig.17).
- If your product is fitted with a connector flange, perform the
assembly steps indicated in fig. 9 before fixing the cooker hood
to the structure. Take connector flange F and fit it to the upper
part of the cooker hood suction assembly using the 2 screws
E (Fig.9).
- Take the upper chimney piece and fix it to the structure using
the 2 screws A (Fig.10). Join the lower chimney piece with the
upper one and fix it carefully using adhesive tape L (Fig.11A).
- Unscrew the 2 screws O, max 3 mm (Fig.11A). Insert the
suction unit inside the structure paying attention that the
previously unscrewed screws O, hook into the slots in the
lower part as indicated in (Fig.11B). Drive in the 3 screws N
(supplied) and tighten the 2 screws O (Fig.11B).
- Fix the air evacuation pipe H (not supplied) onto the connec-
tion flange F (Fig.12).
- Remove adhesive tape L and rest the lower chimney piece
above the cooker hood (Fig.13).
- If the cooker hood is supplied with a lower chimney piece
that must be fixed to the hood body with screws, remove the
anti-grease filters from the hood by acting on the relevant
handles (Fig.16).
- If necessary, fix the lower duct to the hood from the inside,
using the screws P (Fig.14). Re-locate the filters in their seat.

USE AND MAINTENANCE

• We recommend that the cooker hood is switched on before
any food is cooked. We also recommend that the appliance is
left running for 15 minutes after the food is cooked, in order
to thoroughly eliminate all contaminated air. The effective
performance of the cooker hood depends on constant main-
tenance; the anti-grease filter and the active carbon filter both
require special attention.
• The anti-grease filter is responsible retaining the grease
particles suspended in the air, therefore it is subject to clogging
with variable frequency according to the use of the appliance.
- To prevent the danger of possible fires, at least every 2
months one must wash the anti-grease filters by hand using
non-abrasive neutral liquid detergents or in the dishwasher
at low temperatures and on short cycles.
- After a few washes, colour alterations may occur. This does
not give the right to claim their replacement.
• The active carbon filters are used to purify the air that is
sent back into the room and its function is to mitigate the
unpleasant odours produced by cooking.
- The non-regenerable active carbon filters must be replaced
at least every 4 months. The saturation of the active charcoal
depends on the more or less prolonged use of the appliance,
on the type of kitchen and on the frequency with which anti-
grease filter is cleaned.
- Regenerable active charcoal filters must be washed by hand,
with non abrasive neutral detergents, or in the dishwasher at
a maximum temperature of 65°C (the washing cycle must be
complete without dishware). Remove excess water without
damaging the filter, remove the plastic parts, and let the
mat dry in the oven for at least 15 minutes approximately at
a maximum temperature of 100°C. To keep the regenerable
charcoal filter functioning efficient this operation must be
repeated every 2 months. These must be replaced at least
every 3 years or when the mat is damaged.
• Before remounting the anti-grease filters and the regen-
erable active charcoal filters it is important that they are
completely dry.
• Clean the hood frequently, both internally and externally,
using a cloth dampened with denatured alcohol or neutral
liquid detergents that are non abrasive.
• The lighting system is designed for use during cooking
and not for the prolonged general lighting of the room. The
prolonged use of the lighting system significantly decreases
the average duration of the bulbs.
• If the appliance is equipped with courtesy lights it is possible
to use them for general room lighting for a prolonged amount
of time.
• Attention: the non compliance with the hood cleaning
warnings and with the replacement and cleaning of the filters
entails risk of fires. One therefore recommends keeping to the
suggested instructions.
• Replacing halogen light bulbs (Fig.19):
In order to replace the dichroic lamps, carefully remove the
lamp from the lamp holder with the help of a small flat screw-
driver or a similar tool.
PLEASE NOTE! In doing this operation, please take care
not to scratch the hood.
Replace the bulbs with new ones of the same type.
• Replacing halogen light bulbs (Fig.20):
To replace the halogen light bulbs B, remove the glass pane
C using a lever action on the relevant cracks.
Replace the bulbs with new ones of the same type.
Caution: do not touch the light bulb with bare hands.
• Replacing LED lamps (Fig.21):
If the appliance version is with LED lamps, the intervention of
a specialised technician is necessary to replace them.