Operating Procedures

Fill the cold water tank (4) with clean cold water
only.
Connect the Detergent Bottle to the detergent
connection point (3) on the machine.
Fill the detergent bottle with approved detergent.
Warning
Unapproved detergent may be harmful or dangerous
to the machine or the operator using the machine. This
may cause irreparable damage to seals and will void
the manufacturer's warranty. Any detergent used must
be non-caustic and safe to use with steam. Please
contact the manufacturer of the detergent if there is
any uncertainty.
Connect the Vacuum Hose to the front of the
machine (7) ensuring it locks into position. To
release the vacuum hose from the socket slide
the red button upwards at the same time as
pulling the hose out.
Anything other
than clean cold
water used in
the water tank
will void the
manufacturer's
warranty.
14
If the Hose becomes damaged the complete hose
must be replaced. Do not attempt this task
yourself, contact a Diversey approved supplier for
replacement.
Connect the Steam Hose to the front of the
machine (8)
Ensuring it is pushed in all the way and the pin on
the flap locks into the hole on the hose.
IMPORTANT
Grease "O" rings on steam pin before
-
connecting.
-
To release the steam hose, lift the flap
and pull.
-
Plug the power cable into a 240 Volt
supply.
IMPORTANT
-
Inspect the electric cable before every
use. If the cable becomes damaged at
any time the complete cable must be
replaced by a Diversey approved
distributor.
-
Never touch the power cable or plug with
wet hands
-
Always unplug the machine when the
machine is not in use when:
o Cleaning the machine
o Any maintenance work is being
carried out
Switch the On/Off switch (10) to the ON position.
Ensure the
steam hose
cannot be pulled
out.