Now, press the
3.5.4 KEY BLOCK FUNCTION
To set this function, press both the MODE and UP arrow buttons for 3 seconds.
To unblock, do the same.
3.5.5 OPEN WINDOW DETECTOR FUNCTION
The device has a built-in sensor that detects any sudden temperature changes that may occur, i.e. when a window is opened, or any other
circumstance that may prevent the radiator from raising the room temperature. This mode activates when the temperature decreases by
3ºC in 5 minutes. This mode stays until this decreasing tendency disappears.
4- MAINTENANCE
- Keep the floor clean to avoid stains on the wall.
- At the beginning of the year's heating season, the inner parts of the radiator should be vacuumed because dust can be accumulated in
the heating element while the time of the year that the radiator is been off.
- The device can be washed with a moistened cloth or with any washing conventional product.
5- TECHNICAL CHARACTERISTICS
Description
Measures
Weight
Voltage
Frequency
Plug
Safety thermostat
Electronic thermostat
Type of protection
Back cover
Front
button to select the number of the day you are copying to. Press
3IN1 COMFORT 1000 W
500x500x70(mm)
10,35 kg.
Technical Characteristics
230 V
50 Hz
Bipolar 10-16A/250 VAC
Automatic – Rated temp. 90 ± 0,5º - Reset temp. 65º ± 10
Temperature Range 18-24 ºC
Class II IP 24
High quality steel
DUAL KHERR
Description
Materials
.
to confirm
16