Translation of the original instructions
•
Battery test result
Result
Battery in good condition
Good condition, to be recharged
Warning
Charge & test
To replace
Defective cells to replace
Charge error
•
Display of the state of charge and the state of health of the battery
1. Press the directional buttons to view the SOC (charge status) and SOH (health status) of the battery.
2. Press «ENTER» to return to the main menu.
TEST OF THE ALTERNATOR CHARGING SYSTEM
1. Select «system test» in the main menu.
2. Ensure that all consumers are off, such as headlights, lights, air conditioning, radio etc. before starting the engine.
3. When the engine is running, one of the following 3 results is displayed :
Results displayed
Starting normal volts
Low starting voltage
No starting voltage detected
4. Press «ENTER» to begin the charging system test.
BATTERY TESTER DBT 350
Results found
GOOD & PASS
VOL : xx.xx V
CCA : xxxx CCA/SAE
IR : xx.xx mΩ
GOOD & RECHARGE
VOL : xx.xx V
CCA : xxxx CCA/SAE
IR : xx.xx mΩ
CAUTION
VOL : xx.xx V
CCA : xxxx CCA/SAE
IR : xx.xx mΩ
RECHARGE & RETEST
VOL : xx.xx V
CCA : xxxx CCA/SAE
IR : xx.xx mΩ
BAD & REPLACE
VOL : xx.xx V
CCA : xxxx CCA/SAE
IR : xx.xx mΩ
BAD CELL & REPLACE
VOL : xx.xx V
CCA : xxxx CCA/SAE
IR : xx.xx mΩ
LOAD ERROR
VOL : xx.xx V
CCA : xxxx CCA/SAE
IR : xx.xx mΩ
Analysis
The voltage is normal. Press "ENTER" to perform load circuit test
The voltage is below the limit. Tune the starter in line with the proce-
dure supplied by the manufacturer.
The starting voltage is not detected. Start the engine again.
Analysis
The battery is operational.
Battery in good condition but low current.
To recharge before any use.
The battery must be maintained. It gradually
weakens the starting capacity of the engine.
There may also be a bad connection between the
vehicle and the battery. Monitor the battery for a
possible replacement.
The battery discharges quickly and is no longer
functional. Replace the battery.
The battery discharges quickly and is no longer
functional. Replace the battery.
At least one of the cells in the battery is in
short-circuit. Replace the battery.
The battery exceeds 2,000 CCA or 200 Ah, or the
clamps are not connected properly. Fully charge
the battery and retest after discarding the other
two causes. If the display remains the same, the
battery must be replaced.
EN