OPERATION MANUAL
Caution: Danger from electrical current. Unplug the power cord
before any work is carried out on electrical parts.
Have all inspections and work to be carried out on electrical
parts done by a specialist. For more extensive tasks contact
customer service.
The brush and suction motor is switched off via the
built-in electronic system
Brush is blocked
–
Unplug the power cord, check brush for any dirt and if
necessary remove the blockage. The unit now has to be
restarted.
Suction turbine switches off, brush head carries on
functioning (red indicator light goes off)
Thermal switch has disengaged motor due to overheating
–
Unplug the power cord, exchange blocked filter or eliminate
suction hose blockage. After approximately 20 minutes, the
unit will start up again.
Suction hose is blocked
Switch off the unit. Remove the flexible hose from the housing
and pull it straight. Use something long to release hose blockage.
–
The suction hose can be disconnected from the unit by
pressing the locking lever. <Figure 11>
Connecting hose is blocked
–
The connecting hose can be removed by pulling out both
ends. Remove the blockage. <Figure 12>
Connection cable not inserted properly
Connect the upper section of the vacuum cleaner to the brush
head. Connect the hose to the brush head and upper section
of vacuum cleaner. Plug the connecting cable with connector
into the socket on the upper section (plug must audibly click into
place). <Figure 13>
Brushes in brush head are not rotating, suction turbine
is running
Hand pipe is not pushed into motor housing properly, or end is
worn down
–
If the end of the pipe has been worn down (due to
vacuuming without first fitting the crevice or upholstery
nozzle), the end switch will not be actuated and the brushes
will not rotate.
Separating the brush head from the upper section of
the vacuum cleaner
•
Undo the connecting cable, release the plug by pressing in
a pointed object (e.g. screwdriver). <Figure 14>
•
The connecting hose can be removed by pulling out the two
ends.
•
Undo both screws at the side of the upper section to the
vacuum cleaner.
10
6. In the event of malfunction
PACER 214 UE / 218 UE
Figure 11
Figure 12
Figure 13
Figure 14