This manual describes the installation and operation of the Model S241E/EP non-catalytic wood heater. This
heater meets US Environmental Protection Agency's emission limits for wood heaters. Under specific
conditions this heater has been shown to deliver heat at rates ranging from 10,600 to 26,100 BTU per hour.
Model No. S241E/EP
This unit has been listed by Warnock Hersey Limited to
meet or exceed ULC S-627 Canada and UL 1482 U.S.
Contact your local building inspector
prior to installation.
A permit maybe required in your area.
2ft(635mm) HIGHER THAN
NEAREST POINT OF
3FT(1M) MIN
FROM ROOF
ROOF WITHIN 10ft(3M)
PENETRATION
MINIMUM OVERALL
G
HEIGHT FROM FLOOR
15FT(5M)
Unit must be placed on a noncombustible floor protection equivalent to 3/8" millboard.
Floor protector must have min. R value of .446
Consult your local building authorities for further information.
HANDLE
Twist spring handle
SPRING
in counter
clockwise motion while pushing on to handle;
spring handle will "thread" down to desired
location.
Desired Burn Setting
Low
Med / Low
Med / High
High
**Performance may vary depending on actual home operating conditions
MADE IN CANADA BY CFM Corporation, 410 Admiral Boulevard, Mississauga, ON L5T 2N6
NOTE: Retain this sheet for future reference
6" Flue Required
Figure A: Clearance from combustible constructions
A minimum clearance of 18" (457mm) to the chimney connector
may be required by the authority having jurisdiction.
From Heater
From Chimney Connector
A
Sidewall..........
18" (457 mm)
D
Sidewall.................25-1/2" (648 mm)
B
Backwall...............15" (381 mm)
E
Backwall................17-1/2" (445 mm)
C
Corner....................7" (175 mm)
F
Corner....................15"
G
Ceiling....................56"
BACK WALL
B
E
8"(203mm)
A
D
*16
**18
C
8"(203mm)
8"(203mm)
Figure "A"
*16"(406mm) U.S.A.
**18"(457mm) Canada
BE SURE TO INSTALL TWO
FULL BRICKS (S16040) IN
CAUTION: Do not open fire-door to a point where it
BAFFLE AS SHOWN
would be in contact with the combustible sidewall.
2 FULL BRICKS
BAFFLE ASSEMBLY
OPTIONAL FAN
An optional heat exchange blower is available for
this wood burning appliance. To order please see
the local dealer where you purchased your appliance.
CAUTION: BRICK FOR ASH DRAWER
MUST BE INSTALLED BEFORE
OPERATION OF WOOD HEATER
Inlet Air Control Settings
Inlet Air Setting
**Approx. BTU Output
Closed Fully
10,600
¼ Open
12,118
¾ Open
19,413
Fully Open
26,100
800-668-5323
Part No S19210 Rev05
5
(381 mm)
(1422 mm)
BACK WALL
C
F
14
12
F
Diseño de colocación de los ladrillos
ITEM NO.
NO.
LEYENDA NO.
1
DOOR ASSEMBLY
1
DOOR - NO GLASS
2&3
GLASS AND GASKET
3
1/8" GLASS GASKET
4
5/8" DOOR GASKET
5
6
AIR CONTROL SPRING HANDLE
7
8
9
10
11
FIREBRICK LT 9"x4-7/16"x1-1/4"
12
FIREBRICK LT 7-1/4"x4-7/16"x1-1/4"
13
FIREBRICK LT - ANGLED
www.cfmcorp.com
9
7
8
1
10
14
13
13
13
13
12
12
12
12
12
12
12
Brick Pattern
Disposition Des Briques
PARTS LIST
LISTE DES PIÉCES
DESCRIPTION
DESCRIPTION
PORTE MONTÉE
PORTE - SANS LA VITRE
VITRE DE JOINT D'ÉTANCHEITÉ
JOINT DE LA VITRE 1/8po
JOINT DE LA PORTE 5/8po
SPRING HANDLE
POIGNÉE À RESSORT
POIGNÉE POUR L'ADMISSION D'AIR
GLASS CLIP
FERRURE POUR LA VITRE
SCREW
VIS
HINGE PIN
GOUPILLE DE CHARNIÈRE
PUSH NUT
ÉCROU À RESSORT
BRIQUE 9"x4-7/16"x1-1/4"
BRIQUE 7-1/4"x4-7/16"x1-1/4"
BRIQUE - COUPLÉE EN ANGLE
4
2
3
6
QTY
PART NO.
LISTA DE PIEZAS
QTÉE
NO.de PC
CANT. ART NO.
DESCRIPCIÓN
UNIDAD DE PUERTO
1
S31030
UNIDAD DE PUERTO SIN VIDRIO
1
S41055
VIDRIO Y EMPAQUETADURA
1
S31109
EMPAQUETADURA DE 1/8" PARA EL VIDRO
3.3'
S15001
EMPAQUETADURA DE 5/8" PARA LA PUERTO
4.3'
S15011
MANGO CON RESORTE
1
S11007
MANGO CON RESORTE PARA EL REGULADOR DEL AIR
1
S11008
PRESILLA PARA EL VIDRIO
1
S37002
TORNILLO
1
S11086
DEPIENDA ALFILER
2
S11005
UNIDAD DEL DEFLECTOR
2
S11090
LADRILLO REFRACTARIO 9"x4-7/16"x1-1/4"
12
S16040
LADRILLO REFRACTARIO 7-1/4"x4-7/16"x1-1/4"
4
S16043
LADRILLO REFRACTARIO - ANGULADO
2
S16042

Publicidad

loading

Este manual también es adecuado para: