INTRODUCTION
Wire Specifications
Use this chart to pull wires in preparation of your installation. Check the national and local building codes BEFORE installation.
INTRODUCTION
DESCRIPTION OF WIRE RUN
Power Wire, secondary DC output
Local Area Network (LAN)
INTRODUCTION
CAT 5e or better Network Cable.
Grounding the Chassis (use grounding lug in CAPXM)
Door Strike
Magnetic Lock
Dry Contact Closure (Most Gate Operators)
Exit Request (REX)
INTRODUCTION
Supervised Input
Wiegand/Proximity Readers
NOTE: Main power supply and control wiring MUST be run in separate conduits. Conduits must be UL approved for low and high
voltage. Refer to the NEC for additional wiring requirements.
INTRODUCTION
Category 5e cabling is the minimum performance category recommended.
Wiring shall be in accordance with the National Electrical Code (ANSI/NFPA 70), local codes and authorities having jurisdiction.
Always provide power from a dedicated source. Plug provided transformer into an outlet wired to its own 10 Amp minimum circuit
breaker. This will prevent two problems:
• Other equipment cannot introduce spikes, noise, surges or dips into the power circuit that will affect the system.
• The system's operation will not be affected if any other equipment develops a short circuit across the power line.
* CAT 5/6 NETWORK CABLE NOTES:
• For outdoor distances exceeding 140 feet (42.7 m), a UL497 compliant primary surge protector MUST be installed at the CAPXM.
• Distances exceeding 328 feet (100 m) may be accommodated with additional hardware (available through third-party sources).
PRE-INSTALL
PRE-INSTALL
PRE-INSTALL
PRE-INSTALL
PRE-INSTALL
INSTALL
INSTALL
WIRE SPECIFICATION
2-Conductor 14 AWG
2-Conductor 16 AWG
2-Conductor 18 AWG
8-Conductor, 24 AWG Twisted pair
INSTALL
12 AWG Copper
2-Conductor 18-22 AWG Shielded
2-Conductor 18-22 AWG
2-Conductor 18-24 AWG Shielded
2-Conductor 18-24 AWG
INSTALL
2-Conductor 18-24 AWG
7-Conductor 18-22 AWG Shielded
INSTALL
9

NETWORK

ACCESS CONTROL
NETWORK
ACCESS CONTROL
MAXIMUM RUN DISTANCE
Up to 300 feet (91.4 m)
Up to 200 feet (60.9 m)
Up to 100 feet (30.4 m)
328 feet* (100 m)
NETWORK
ACCESS CONTROL
12 feet (3.7 m)
100 - 250 feet (30.5 - 76.2 m)
50 - 125 feet (15.2 - 38.1 m)
500 - 2500 feet (152.4 - 762 m)
500 feet (152.4 m)
NETWORK
ACCESS CONTROL
500 feet (152.4 m)
500 feet (152.4 m)
NETWORK
ACCESS CONTROL