3.2 RECEIPT, UNPACKING, PRELIMINARY OPERATIONS
Before proceeding with installation, check:
• that the packaging is intact and has no defects
• that all the elements have been provided for assembly of the same with perfect verticality of the
surfaces on which the door will be installed (check with plumb line/laser level etc.)
In case of uncertainty, contact the manufacturer for any clarification.
3.3 MECHANICAL INSTALLATION
3.3.1 Installation hole
For installation of the door a hole is required in the wall with the dimensions indicated in Fig. 1, where:
H = free light height of the door,
L = free light width of the door.
Warning, above height H it is necessary to provide enough space for the top part, equal to:
- at least 600 mm for the 590 mm version
- at least 450 mm for the 420 mm version
3.3.2 Frame assembly
Near the installation hole, clean the floor and place the two vertical uprights and the crossbar on the
ground.
VERSION 590 mm
The joining element is on the upper part of the two uprights. Line up the holes with those in the guide
support and secure everything with the screws provided, M8X20 (Fig. 2).
Repeat the operation on the second upright.
VERSION 420 mm
There are two joining elements in the lower part of the crosspiece.
Insert the protruding ends inside the upper part of the two uprights. (Fig. 3).
Place a pallet under the crosspiece (it will be needed for the lifting operation) as described in the image
(Fig. 4). Then proceed to lift the pallet with a fork lift truck, an operator must accompany the uprights on
side to reduce the sliding on the ground to a minimum.
3.3.3 Positioning and holes
The door must be positioned with the uprights perfectly perpendicular to the ground, and the upper part
straight; use a spirit level, aligners or plumb line in this phase. There are slots in the two uprights, in a
central position; drill with a Ø13 bit for inserting the M12 tie rods (Fig. 5). On the ground, drill and secure
the two dowels for locking the uprights.
VERSION 590 mm
Make three Ø13 holes on the wall, on the right upright and three holes on the left upright corresponding
to the holes on the bearing support (Fig. 5
VERSION 420 mm
Create a Ø13 hole on the wall, on the right upright and one on the left upright corresponding to the slot
on the metal back of the crosspiece. (Fig. 5
04030562EN 09 2021-03
Roll Up Door with membrane keypad
version 590
mm).
version 420
mm)