3. BUTTONS AND CONTROLS

DOWN Key:
Reset PEAK Value
The keypad on the readout meter is equipped with three pressure-sensitive
buttons that provide easy access to all functions and features.
Press and hold down the MENU (ON/OFF) button to turn the meter ON.
The UP and DOWN arrows to the left and right of the MENU button provide
access to all displays and features. Selected menu items appear highlighted in
blue. Selected Menu items can be confirmed by pressing the MENU button once.
Pressing the DOWN arrow (while in OPERATION MODE) will reset the PEAK
value (highest recorded luminescence since last reset) for visible, UV, and if
applicable, blue light sources. If using the AccuPRO Plus (XP-4000), the UP
arrow toggles between Visible/UV and blue light readouts.
Press and hold the MENU button in OPERATION mode to turn the unit OFF.
Highlighting and selecting the BACK button will return the user to the previous
screen without making any changes.
4. OPERATION––QUICK GUIDE
1. To turn the meter on, press and hold the MENU button for two seconds. It is recommended
to fully charge the unit before use (see section 10.3).
2. The Spectroline
your device will briefly appear as well. Select INFORMATION from the MAIN MENU screen
to thoroughly examine information pertaining to your device (see Section 6).
3. After loading, the unit will boot directly to Operation mode, displaying visible and UV readings
by default. To view levels of blue light with the AccuPro Plus (XP-4000), press the UP button.
4. To change meter display settings, press MENU. Then select the SETTINGS option. When
highlighted, press MENU to enter SETTINGS menu (see SETTINGS section for details).
5. To take a measurement, enter Operation Mode. Shine a light source directly over the center
of the sensor. The measurement will display on the interface screen.
6. The meter instantly displays light level data for each wavelength (intensity/unit area).
7. To turn off the meter, press and hold the MENU button for 2 seconds while in Operation mode.
The display will then power off. Wait at least 30 seconds after the meter powers down before
performing a RESTART (by pressing and holding MENU for 2 seconds). The AccuPRO will
only power off from Operation mode, and not from the menus.
8. To both conserve battery life and preserve the sensitivity of the sensor head, utilize the "Set
Auto-Off" function under the "SETTINGS" menu. (See section 6).
UV-A Reading
UV PEAK Value
Visible Reading
VIS PEAK Value
MENU Key:
Adjust settings, confirm choices
®
loading screen will appear as the unit powers ON. Information pertaining to
Operation Mode for Visible and UV Light Sources
5
UP Key:
Toggle VIS/UV or
BLUE modes
(XP-4000 only)
Battery Indicator
Units