Especificaciones técnicas
Code
0x80 (128)
Festo — SDAS-MHS — 2020-03a
Additional Code
0x30 (48)
0x31 (49)
0x32 (50)
0x33 (51)
0x34 (52)
0x35 (53)
0x36 (54)
0x40 (64)
0x41 (65)
0x82 (130)
Name
Parameter value out of
range
Parameter value above
limit
Parameter value below
limit
Parameter length ove-
rrun
Parameter length unde-
rrun
Function not available
Function temporarily
unavailable
Invalid parameter set
Inconsistent parameter
set
Application not ready
Description
Written parameter va-
lue is outside its per-
mitted value range
Written parameter va-
lue is above its speci-
fied value range
Written parameter va-
lue is below its speci-
fied value range
Written parameter
length is above its pre-
defined length
Written parameter
length is below its pre-
defined length
Written command is not
supported by the devi-
ce application
Written command is not
available due to the cu-
rrent state of the device
application
Written single parame-
ter collides with other
actual parameter set-
tings
Parameter inconsisten-
cies were found at the
end of block parameter
transfer, device plausi-
bility check failed
Read or write service is
refused due to a tem-
porarily unavailable ap-
plication