Model: 28173 / ZW4104
ADVANCED OPERATION
The following Advanced Operation parameters require that you have an advanced controller like the model 45601
LCD remote. Advanced remotes from other manufacturers may also be able to change these settings; however,
basic remotes do not have this capability.
All On/All Off
Depending upon your primary controller, the 45603 module can be set to respond to ALL ON and ALL OFF
commands in up to four different ways. Some controllers may not be able to change the response from its default
setting. Please refer to your controller's instructions for information on whether or not it supports the
configuration function and if so, how to change this setting.
LED Light
When shipped from the factory, the LED is set to turn ON when the connected light is turned OFF. This is the
default setting and can be changed if your primary controller supports the node configuration function. To make
the LED turn ON when the light is turned ON, change parameter 3's value to "1". To turn the LED OFF at all
times, change parameter 3's value to 2.
• Parameter No: 3
• Length: 1 Byte
• Valid Values = 0, 1 or 2 (default 0)
Z‐Wave Plus Interoperability Statement
This product can be included and operated in any Z‐Wave network with other Z‐Wave certified devices from other
manufacturers and/or other applications. All non‐battery operated nodes within the network will act as repeaters
regardless of vendor to increase reliability of the network.
While these units are still in development, we have not fully completed all of the instruction
manuals for these products.
Since these are designed the same way as our previous Z‐Wave models, we have provided the
instructions from them and labeled which will correspond with each model number.
The Manual Reset (Factory Default) instructions required for Z‐Wave Plus are listed below for
each model.
Manual Reset (Factory Default) Instructions
1. Press and hold the top button while you plug the device into AC power, continue holding for at
least 3 seconds.