PoolOne Peristaltic Pump | Models: CS · RG · pH · ORP
WARNING!
These products are DANGEROUS (IA) and require special precautions during use, handling and storage.
• NEVER mix chemical products.
• NEVER allow children or people who have not read this manual to use or tamper with PoolOne or any of its
peripheral components (including chemical products).
pH chemical products:
• ABSOLUTELY not recommended => pure sulphuric acid
• Recommended for lowering pH => negative pH (with a sulphuric acid base)
• Recommended for raising pH => positive pH (sodium carbonate or bicarbonate)
ORP chemical products:
• ABSOLUTELY not recommended => all types of organic chlorine
• Liquid chlorine or 12% bleach can be used neat. If the product has a concentration of 48%, it is necessary to dilute it in
water in a 1:3 ratio.
The pH / ORP probes are subject to wear and tear and therefore are not covered by the warranty.
2
INSTALLATION INSTRUCTIONS
Probe positioning
For optimum probe
reading, position it
perpendicular to the
tubing.
Installation plant
0000138968
Make sure that the injection pressure is below 1.5 bar
The probe's angle of
inclination must never
exceed 45° from
vertical.
rev. 1.0
EN
Warning!
2 m
Warning!
Use with salt chlorinator:
For the pH systems, to prevent the
risk of system malfunctioning or
damage, observe the following
instructions:
1.
Position the pH measuring
probe prior to the chlorinator
cell.
2.
To eliminate eddy currents,
connect the pool water to an
electrical ground point
3.
Position the product injection
point after the chlorinator cell.
2