PoolOne Peristaltic Pump | Models: CS · RG · pH · ORP
5.5
PoolOne ORP
Constant dosing with pH control meter built in, the pump has galvanised electrical insulation and measure
insulation
Switch position:
a.
MOM: Priming position. The pump is running.
b.
ON: Normal position. The unit measures the ORP and doses.
c.
OFF: Stand by position. The pump is stopped.
Setup
a.
Set the switch to OFF position.
b.
Keep pressed
c.
ORP setup menu:
Adjust the dosage method for ORP: High ("Hi") or Low ("Lo")
1.
2.
Temperature (fixed value): 25°C
Set Point adjustment
a.
Set the switch to ON position.
b.
Keep pressed
c.
After 3 seconds from releasing the
It is possible to set a value between 400 and +999 mV, with an increase of 10 mV.
When the real measure is lower than 400 mV or higher than 999 mV, the measure displayed flashes.
Set the switch to ON position then follow the steps below:
H
O
2
5 s
Set Redox calibration
Note: During calibration procedure, the hold (setup) LED will turn red.
0000138968
for 3 seconds to enter the SETUP menu.
until the Setpoint value starts flashing, then press again
key, the unit saves the value and displays mem.
1
5
9
2
6
10
Save and exit
rev. 1.0
EN
to increase the value.
3
7
60 s
11
4
465mV
8
6