 Check that the available voltage is not higher than the one stated on the rear panel of the unit.
 The power cord should always be in perfect condition: switch the unit immediately off when the power cord
is squashed or damaged. It must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard
 Never let the power-cord come into contact with other cables!
 Due to safety reasons it is prohibited to make unauthorized modifications to the unit.
FUNCTIONS
1. PROJECTOR MAINS OUT: 230V power output to the connected projector.
2. MAINS POWER IN/OUT: used to connect the 230V power cable that goes from one box to the next.
3. POWER TERMINAL BLOCK: 15A contacts to make the junction of the main power cable.
4. PROJECTOR DMX IN/OUT: used to connect the DMX-cables going to and coming from the connected
projector.
5. MAIN DMX IN/OUT: used to connect the main DMX-cable that goes from one box to the next.
6. DMX TERMINAL BLOCK: press contacts to make the junction of the main DMX-cable
7. RUBBER SEALING: makes the junction box 100% waterproof. After installation make sure that it is well
installed before closing the unit.
8. SCREWS: make sure these screws are tightly fastened to assure that the unit is waterproof.
CONNECTIONS
IMPORTANT: The electrical installation should be carried out by qualified personal only, according to the
regulations for electrical and mechanical safety in your country!
Please check the example drawing below to see how the junction box should be cabled: