RE A D AND S AV E TH E S E IN S T R UC TIO NS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. This unit must be grounded.
7. Do not connect this product as a load on a fan speed control or
light dimmer.
8. Read and understand entire instructions before proceeding with
installation.
WARRANTY
BROAN-NUTONE ONE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products that such products
will be free from defects in materials or workmanship for a period of one year from the date of
original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge,
any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, AND FUSES.
This warranty does not cover (a) normal maintenance and service or (b) any products or parts
which have been subject to misuse, negligence, accident, improper maintenance or repair
(other than by Broan-NuTone), faulty installation or installation contrary to recommended
installation instructions.
The duration of an implied warranty is limited to the one-year period as specified for the
express warranty. Some states do not allow limitation on how long an implied warranty lasts,
so the above limitation may not apply to you.
BROAN-NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE'S OPTION, SHALL
BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE
SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT
OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the
exclusion or limitation of incidental or consequential damages, so the above limitation may
not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary
from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone
number below, (b) give the model number and part identification and (c) describe the nature of
any defect in the product or part. At the time of requesting warranty service, you must present
evidence of the original purchase date.
Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711
Intelligent Ventilation System
®
INSTALLATION
Install controls and wire them as shown. Use following guidelines:
• IMPORTANT:
• Use minimum 75 °C rated electrical wiring.
• Except for required neutral wire, these controls install like
• Specify deep device electrical boxes where controls will be
• All controls must be grounded using attached ground wire.
MODELS SSQTXE080 • SSQTXE110
LINE
Black
GROUND
POWER
Bare
Copper
LINE
(GFCI
protected
if required)
NEUTRAL
White
QTXE080 Ultra Silent™ fan must be wired to SMSC080
SmartSense
control.
®
QTXE110 Ultra Silent™ fan must be wired to SMSC110
SmartSense
control.
®
normal switches. Make sure electrician knows each control
location must have a neutral wire. Neutral wire at switch
locations may be code requirement or regular practice in
installation municipality; but unless explicitly specified,
electrician might not install it.
installed. These controls fit in most North American electrical
boxes; however, deep boxes provide extra working space which
eases installation. Labor cost savings can offset higher box
costs, which is usually less than a dollar over standard depth
boxes. Use boxes that have 18 cu. in. minimum volume and
are at least 1-1/2 in. deep.
Page 1
LINE
Black
MASTER
GROUND
or SLAVE
Bare
CONTROL
Copper
LOAD
Red
NEUTRAL
White
WHITE
BLACK
GROUND
Green
FAN

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Broan-NuTone SmartSense SSQTXE080

  • Página 1 This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part.
  • Página 2: Control Operation

    MODELS SSQTXE080 • SSQTXE110 Page 2 CONTROL OPERATION HOW SYSTEM WORKS INDOOR AIR QUALITY NETWORK Broan SmartSense system is design to provide recommended ® A single Broan SmartSense system is powerful enough to fulfill ® ventilation for desirable indoor air quality. Related ventilation ventilation rates for larger homes;...
  • Página 3 MODELS SSQTXE080 • SSQTXE110 Page 3 HOW TO SET SYSTEM LEVEL TABLE A Bedrooms Installer, homeowner, or building science expert may adjust Broan Floor Area (ft SmartSense ventilation system level. ® 0 - 1 2 - 3 4 - 5 6 - 7 >...
  • Página 4 MODELS SSQTXE080 • SSQTXE110 Page 4 Selection mode. Fan and LED will turn on for one to two seconds 2. Remove white paddle/frame from control. and then turn off. Caution: Do not touch or put anything inside control housing; 1. Make sure fan and LED are off; press and release Off paddle. control damage may result.
  • Página 5: Sistema De Ventilación Inteligente Smartsense

    El cable Durante este período de un año, Broan-NuTone, a su criterio, reparará o reemplazará sin cargo alguno cualquier neutro en las ubicaciones de los interruptores puede tener un requisito pieza o producto que se encuentre defectuoso bajo condiciones normales de uso y servicio.
  • Página 6: Funcionamiento Del Control

    MODELOS SSQTXE080 • SSQTXE110 Página 6 FUNCIONAMIENTO DEL CONTROL CÓMO FUNCIONA EL SISTEMA Las instalaciones múltiples se comunican a través de los circuitos eléctricos de la vivienda, para formar una red de calidad de aire interior. Las rutas de El sistema SmartSense de Broan está...
  • Página 7 MODELOS SSQTXE080 • SSQTXE110 Página 7 CÓMO CONFIGURAR EL NIVEL DEL SISTEMA TABLA A Recámaras El instalador, el propietario de la vivienda o el experto en construcción Superficie pueden ajustar el nivel del sistema de ventilación SmartSense de Broan. ® del piso (pies 0 - 1 2 - 3...
  • Página 8 MODELOS SSQTXE080 • SSQTXE110 Página 8 la paleta ON hasta que el LED se encienda y se apague cada segundo (destello 1. Utilice un desarmador Phillips N. 1 magnético y retire los cuatro lento). El ingreso del modo de selección de función de apagado automático/retardo (4) tornillos de la paleta/bastidor color blanco.

Este manual también es adecuado para:

Smartsense ssqtxe110

Tabla de contenido