This motor has been designed to work with a stable power source
●
circuits for lighting Always connect the motor to the grounding system (yellow/green)
a device with a voltage category III, i.e. the distance between the contacts must be of 3,5 mm at least
●
with maintained position
Command buttons are connected to the main voltage, so they must be properly insulated and protected
proportionate to their length and to the absorption of the load, and in any case not less than 1,5 mm
03.2 Power supply
Connect the motor as shown in the diagram. It is mandatory to connect the motor to the grounding system. The electrical specifications of the motor are shown on
the label applied to the motor tube.
03.3 Command button
A momentary position button ("hold-to-run") with mechanical interlock must be used, do not use maintained position switches. It is absolutely forbidden to
connect several control buttons in parallel! The control button is subjected to the mains voltage and must therefore be adequately insulated and protected.
04. INSTALLATION
44
10
2x4,5 Nm
2x9,5 Nm
L (mm)
156
1
L
●
Make connections with power supply disconnected Check that the power supply does not depend from electrical
1
L
190
22
1
2
BLUE
BLACK
NEUTRAL
MANOUVRE 1
L
N
●
The supply line must be equipped with a circuit breaker. The supply line must be fitted with
●
You must use buttons with spring return ("hold-to-run" type), do not use buttons