BIO UV UV10 Manual De Instalación Y Mantenimiento página 3

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
BIO-UV
We thank you for choosing a BIO-UV ultraviolet water treatment system.
Our equipment has been designed to offer you operational reliability in total confidence
for many years.
Warnings and safety
Exploded view
Detailof the parts
Parts list
Dimensions
Standard installation
Electrical Connections
Wiring Diagram
Maintenance
Guarantees
DESCRIPTION
Maximum pressure in Use
Maximum flow rate (m
(after pressure losses)
EXPOSITION TIME / secondes
PERFORMANCE In millijoules at the actual flow
rates recommended above.
(mandatory standard for drinking water: 25mj)
BALLAST
LAMP (nomber and power)
SERVICE LIFE of LAMPS
DIMENSION of the UV CHAMBERS in cm
DIAMETER of the UV CHAMBERS in cm
OVERALL HEIGHT in cm
WEIGHT POIDS (without water) kg
CAPACITY IN LITRES
INPUT/OUTPUT (diameter in mm)
with Unions supplied
CONTENTS
The BIO-UV equipment is ready to be installed.
No intervention is required inside the equipment.
A simplified quick assembly procedure is provided.
3
/h)
Copyright BIO-UV 03/07/08
UV 10
UV 20
3 Bar
3 Bar
7
12
2,8"
2,6"
25 mJ
25 mJ
1
1
1 x 33 W
1 x 55 W
13 000 h
13 000 h
32
58
15
15
42
69
7,6
9
6,40
11,70
50
50
Page
4
5
6
7
7
8
9
11
12
13
UV 30
UV 40
3 Bar
3 Bar
20
28
2,3
2,1
25 mJ
25 mJ
1
1
1 x 87 W
1 x 114 W
13 000 h
13 000 h
83
108
15
15
94
120
11
14
17,30
22,40
63
75