Safety Considerations - Dustcontrol RAF 1600 Manual Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22

Safety Considerations

Read all instructions before the machine/installa-
tion is commissioning.
The equipment must be installed and maintained
properly by qualifi ed personnel who have study
this user instruction. Dustcontrol does not take
responsibility for defective installation or mainte-
nance.
Warning! When using electric machines, basic
safety precautions should always be followed to
reduce the risk of fi re, electric shock and personal
injury, including the following:
1. Important!
No hot particles nor ignition sources are allowed
to be sucked into the unit. The machine should
not be used for explosives, unstable or pyrop-
horic particles.
– WARNING!
be adequately instructed on the use of these
machines.
– WARNING!
dry use only.
– CAUTION!
indoor use only.
– CAUTION!
be stored indoors only.
2. Work area environment
Keep the area around the central unit clean.
Do not store or work with fl ammable liquids or
gases near the machine.
3. Overload
If there is an alarm signal it should be care-
fully checked out to see that the machine is
un damaged. If there are any damaged parts
these should be repaired by a Dustcontrol
authorized service centre. Always follow the
regulations pertinent to the material you are
working with. Do not use the machine for pur-
poses that it is not intended for.
4. Bodily injuries
Warning - High negative pressure
Do not start the fan without having it con-
nected to the duct work. Never let the suction
come in contact with parts of the body, for
2017-09-04
5. Electricity
6. Important measure
Operators shall
7.
This machine is for
This machine is for
This machine shall
8. Warning
RAF 1600/2500 - 11
example a hand. The pump generates a high
negative pressure, severe injury may result.
Warning - Very hot exhaust air
Exhaust air can be very hot.
A separate lockable disconnect must be instal-
led where it is readily accessible to the pump.
Do not repair the electric compo-nents your-
self, get somebody qualifi ed. Faults may cause
injury. The electrical connections may only be
performed by a certifi ed electrician. See also
under section 8, 'Warning'.
The electrical disconnect should be locked in
the "off" position before demounting the safety
panels or ducting.
Checking for damage
Check the machine regularly for damage. If
there are any damaged parts these should be
repaired by a Dustcontrol authorized service
centre.
If the supply cord is damaged, it must be re-
placed by the manufacturer, its service agent
or similarly qualifi ed persons in order to avoid
a hazard.
Use only accessories and replaceable parts
which are available in the Dustcontrol catalo-
gue. When using non-genuine parts, especi-
ally fi lters and plastic sacks, dust leaks could
occur which may be hazardous to health.
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they
have been given supervision or instruction
concerning use of the appliance by a person
responsible for their safety. Children should be
supervised to ensure that they do not play with
the appliance.
This machine is intended for commercial use
only, for example in hotels, schools, hospitals,
factories,shops, offi ces and rental businesses.
Part No 9053/9054-A

Publicidad

Tabla de contenido
loading

Productos relacionados para Dustcontrol RAF 1600

Este manual también es adecuado para:

Raf 2500

Tabla de contenido