Do not connect 50 Hz electrical loads to a
60 Hz product.
1. Start the engine and let it become warm for some
To start the product on page 8 .
minutes. Refer to
2. Connect and start the electrical loads.
3. Make sure that there is no overload in the product.
To prevent overload in the product on page
Refer to
9 .
To prevent overload in the product
Overload in the product can cause damage to the
product and to connected electrical devices. Do the
steps that follow to prevent overload in the product.
•
Add the total amount of W of all electrical devices to
be connected at the same time.
CAUTION: The total W must not be
more than the W capacity of the product.
Introduction
WARNING: Read and understand the safety
chapter before you do maintenance on the
product.
Maintenance
Clean the product.
Do a check of the engine oil level.
Do a check of the air filter.
Clean the air filter.
Do a check of the deposit cup.
Replace the engine oil.
Clean or replace the air filter.
Do a check of and clean the spark plug.
Do a check of the idle speed. Adjust the idle speed
if it is necessary.
Do a check of the valve clearance. Adjust the valve
clearance if it is necessary.
Clean the fuel tank, fuel strainer and carburetor.
1420 - 002 - 02.03.2020
•
The rated W of lights can be used from light bulbs.
The rated W of tools, equipment and motors can be
found on a decal on the device.
•
If there is no amount of W specified in the product,
tool or equipment, multiply V with the rated A value.
•
Always connect electrical devices with the highest
start up W to the product first. Then add the W of all
other connected electrical loads.
To stop the product
1. Stop and disconnect the electrical loads from the
receptacles on the control panel.
2. Let the engine operate without load for 30 seconds.
3. Set the power switch to the OFF position.
4. Close the fuel valve.
Maintenance
Maintenance schedule
* Clean at a more regular interval if the product is used
in conditions with much dust.
** Maintenance must be done by an approved servicing
dealer.
Daily
mainte-
20
nance
hours or
before
each
opera-
month
tion
X
X
X
X
X
X*
WARNING: Do not stop the engine if the
electrical loads are on and connected to
the product.
Maintenance interval in hours
300
50
100
hours or
hours or
hours or
1 time
each 3
each 6
each
months
months
year
X*
X
Each 2
years
X**
X**
X**
9