ULTRA NUMBER KEYPAD MODULE
Module with number keypad for Ultra entrance panel, compatible with all systems. Can be used as a module
for calling the user directly when the code is known and for access control with the activation of built-in relays
and audio or audio/video module outputs, and system actuators. The access codes may be Permanent (always
valid), metered (valid for a certain number of uses) or associated with a validity date. In the latter case, each
code can be assigned a validity start/end date, dual daily time band and validity days. Each access code can
be assigned up to 4 different actions. The playback function for playing the relevant audio message when
each button is pressed can be enabled. There is also an event log, complete with all information (activated
codes, user that used them, users called, etc.), which can store up to 1275 events. It has a Wiegand output for
interfacing with access control systems. Automatic button backlight deactivation during daylight hours using
the twilight sensor for the paired audio or audio/video module. Anodised aluminium alloy coating. Dimensions:
100x90x35 mm (1 Ultra module).
THE MAIN FUNCTIONS AVAILABLE ARE AS FOLLOWS:
• Access code entry. The access codes may be Permanent (always valid), metered (valid for a certain number
of uses) or associated with a validity date. In the latter case, each code can be assigned a validity start/end
date, dual daily time band and validity days.
• Each access code can be assigned up to 4 different actions which will be carried out consecutively.
• Call code entry. The call function is enabled by default. It can be disabled.
• Activation of playback of the corresponding audio message when each button is pressed (e.g. if you
press 2 on the number keypad, audio message "two" will be played).
• Event log complete with all information (activated codes, user that used them, users called, etc.). Up to
1275 events can be saved in the memory.
• "Trade" function. On specific days of the week and in specific time bands, simply pressing the key button
(without entering any code) will activate the output associated with the keypad without an external clock.
INSTALLATION
System requirements: Min. operating system Windows 7-64bit, min. NET Framework: 4.7.2, min. CPU
2GHz Dual Core, min. RAM 4GB; min. free memory 200MB
Download the ViP Manager software from the website pro.comelitgroup.com and run the installation file,
following the on-screen instructions.
Connection to number keypad art. UT9279M
8
1210
1210A
1595
1440+1441