10
STERILIZERUV PS
OPERATING MANUAL
INTRODUCTION, PURPOSE
Dear Customer, we congratulate you on your excellent choice of high quality ultraviolet
sterilizer, intender for water sterilization in water gardens, garden ponds and fish ponds.
Prior to installation of the device please read these instructions carefully. Persons unfamil-
iar with these operating instructions should NOT operate this device.
PARTS LIST /see fig. 1/
No.
Part name
1
Complete housing
2
Mounting bracket
3
Complete fitting, including:
3a
Complete stabilizer
3b
Frame
3c
Starter socket
3d
Fluorescent lamp fitting
4
Screw cup
5
Screws 3,1x10
6
Stopper
7
Gasket 26x3,5
8
Starter
9a
Head
9b
Quartz tube
10
Gasket 26x3,5
11
Gasket 53x3
12
UV fluorescent tube
13
Connecting stub
14
Setting bush with thread
15
Quart tube gasket 38x3
16
Distance sleeve
PS – 15 W
PS – 30 W
PS – 55 W
101765
101766
101766
101766
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3,1x10
3,1x10
3,1x10
-
-
-
26x3,5
26x3,5
26x3,5
-
-
-
-
-
-
-
-
-
26x3,5
26x3,5
26x3,5
53x3
53x3
53x3
200389
200097
200232
100241
100241
100241
-
-
-
38x3
38x3
38x3
-
-
-
TECHNICAL SPECIFICATION
Voltage: 220-240 V
Frequency: 50 Hz
Types
T8 (T26) UV-C
Fluorescent tube length – without
connectors [mm]
Power consumption [W]
Max. pressure [bar]
Max. pond volume [m
3
]
Max. pump output [l/h]
Recommended AQUAEL pump
Net mass [kg]
Degrees of protection of enclosure: IP X8
LIST OF FIGURES
1. Sterilizer parts
2. Removal of fitting from the housing
3. Placing the fitting in the housing
4. Cleaning of the gasket
5. Removal of fitting from the cover
6. Replacement of fluorescent tube and starter
7. Cleaning of the housing gasket (7)
8. Quartz tube replacement
DEVICE SPECIFICATIONS
Water pumped through the device flows in a thin layer directly within the range of UV-C
ultraviolet radiation, which destroys algae, bacteria and other pathogenic organisms. Ow-
ing to the operation of the sterilizer, water always remains clean in the biological sense,
and fish and plants live in a comfortable and healthy environment – you can forget green
water with algae forever.
Important features, distinguishing the STERILIZERUV:
· this is an external device, designed to be installed outside of the pond (out of water);
· thermal switch (installed in the stabilizer) –in abnormal operating conditions (e.g. when
the stabilizer is covered or the starter is damaged) it shut off power supply to the sterilizer
until it cools down. Restart will take place automatically;
· 10-meter power supply cord enabling comfortable location of the device;
· metal housing ensuring high durability of the device;
· universal connectors – enable adaptation of device inlet and outlet diameter do the
plumbing diameter applied in water circulation in the given case.
SAFETY PRECAUTIONS
Before the installation and every starting of the device, carefully read this installa-
tion and maintenance manual.
When performing any works conducted in the water reservoir (startup, mainte-
nance), disconnect the device from the mains by pulling the plug out of the socket.
The device emits ultraviolet radiation that is harmful to human skin and eyes. Never
operate the device with its housing removed!
The device should only be powered from an electricity network with the nominal
parameters (voltage and frequency) specified on the housing of the device, using
a socket located in a dry place. The power supply network should be equipped with
a residual-current circuit breaker with a leakage current of 30mA.
11
ENGLISH
PS – 15 W
PS – 30 W
PS – 55 W
15 W
30 W
55 W
437
893
893
22
36
68
0,5
0,5
0,5
15
30
50
3500
7000
9000
PFN 3500
PFN 7500
PFN 10000
2,72
3,00
3,10