Graf Integra Puesta En Marcha Y Localización De Averías página 5

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

FAULT
Pump does not switch on
automatically
Motor runs,
pump does not deliver
Pump does not switch off
automatically
Pump constantly switches on
and off
Low delivery rate
Motor has stopped or
does not start
Pressure fluctuations
Otto Graf GmbH
Kunststofferzeugnisse
Troubleshooting submersible
pump Integra INOX
CAUSE(S)
No water present
Motor overheated
Suction head too high
Pressure switch faulty
Geodetic height above pump greater than 10 m
Impeller dirty
Filter dirty
Air in pump or suction line
Pump does not prime
Leakage on pressure side
Leakage on the pressure side (e.g. Geka
quick couplings)
Non-return valve not fitted on suction side
Non-return valve defective
Draw-off volume too low
Pressure hose diameter too small
Pressure line improperly fitted. Stopcock too
close to the discharge port
Pressure line clogged / kinked
Suction line clogged / kinked
Non-return valve dirty
Suction filter dirty
Sucking in air
No voltage present
Plug not connected
Dry run protection is activated
Thermal protection has tripped
Condenser defective Electronics defective
Leakage on pressure side or suction side
Non-return valve not fitted or dirty
Impeller dirty
4/8
Carl-Zeiss-Straße 2 – 6
DE-79331 Teningen, Germany
REMEDIAL ACTION(S)
Check water level
Allow pump to cool down
Check installation, reduce suction head if
necessary
Exchange by qualified personnel
Reduce delivery head
Clean the impeller, see illustration
Clean
Start pump several times
Check water level and suction line
Eliminate leakage (air leaks are often water-
tight, i.e. "invisible"!)
Eliminate leakage (e.g. seal screw connections
properly).
Fit the non-return valve
Check and replace non-return valve
Open the shut-off valve completely and use
a hose with a larger diameter of min. ¾"
Install pressure line without bends and stop-
cock min. 1m away
Clean / remove kink
Clean
Check the tightness and routing of the
suction line and connections.
Check power supply
Insert plug
Check water level
Motor overheated. Allow to cool down with
the plug disconnected
Exchange by qualified personnel
Properly seal all screw connections,
couplings, etc.
Fit or check and clean the non-return valve
Clean the impeller, see illustration
Tel.: +49 7641 589-0
Fax: +49 7641 589-50
mail@graf.info
www.graf-online.de

Publicidad

Tabla de contenido
loading

Tabla de contenido