ACCESSING PROGRAMMING MODE

Programming mode may be used to confi gure operation of the device and to save or edit access
codes.
Press
,
,
Enter the master password and press
The device will beep 3 times to confi rm. The button
state.
Either hold
pressed for at least 5 seconds or leave the device inactive for more than 30 seconds to quit
programming mode.
The button
turns from red to blue and the device switches to normal operation.

RELAY OPTIONS PROGRAMMING PROCEDURE

Access programming mode.
Enter the confi guration code nn a b ss where:
nn is the relay to be confi gured; possible values are:
31 = relay 1
32 = relay 2
a
defi nes whether the code needs to be confi rmed by pressing button
1 = relay activation entering the code only
2 = relay activation entering the code and pressing the button
b
defi nes the relay activation mode; possible values are:
1 = monostable activation
2 = toggle activation
ss defi nes the activation time expressed in seconds; possible values are:
00 = 200 ms (set this value for toggle operation)
01 = 1 second
.
99 = 99 seconds
For installing the access control keypad Ref. 1723/46 on control panel Mod. 1784, the pedestrian
gate lock activation time will be constrained by the panel (max. 9 seconds).
Press
to confi rm.
The device generates 3 confi rmation beeps and the button
If the entered code is wrong, the device will generate one long beep and wait for the correct code to be
entered.
Either hold
pressed for at least 5 seconds or leave the device inactive for more than 30 seconds to quit
programming mode.
The button
turns from red to blue and the device switches to normal operation.

ACTIVATION CODE STORAGE PROCEDURE

Access programming mode.
Enter confi guration code nn xxxxxxxx where:
nn
defi nes the code memory location; possible values from 01 to 22.
xxxxxxxx activation code (from 3 to 8 digits).
Press
to confi rm.
Defi ne the number of relays to be activated with the code shown:
1 = relay 1
2 = relay 2
Press
to confi rm.
The device generates 3 confi rmation beeps and the button
If the entered code is wrong, the device will generate one long beep and wait for the correct code to be
entered.
DS1723-008B
in sequence.
.
turns from blue to red: the device is in programming
to confi rm.
turns from red to blue to red.
turns from red to blue to red.
or not; possible values are:
11

Publicidad

Tabla de contenido
loading

Tabla de contenido