Installation

Cross-section of final installation

The WaterWell is designed to provide reliable fresh water to your livestock all year round.
When installing the WaterWell pay attention to the following areas:
Choose a location where the tank will be sheltered from the elements.
The vertical water supply line and the horizontal water supply line should all be installed to reach more than
1 foot (305 m) below the usual frost line.
The concrete slab should have a 4 inch (102 mm) by 24 inch (610 mm) apron from the tank to the concrete
edge.
Ensure that the placement of the water access hole in the concrete aligns with the anticipated placement of the
water access cavity of the waterer.
WaterWell 2: Make sure that your vertical water supply line with ¾ inch male NPT fitting attached is
¾ - 1 inch (19 - 25 mm) below the top of concrete.
WaterWell 4: Make sure that your vertical water supply line with ¾ inch male NPT fitting attached is
2 inches (51 mm) above the top of concrete.
The water supply line should be centered in the thermal earth tube (if using) to help discourage frost formation.
To be effective, the thermal earth tube(s)* must be installed to reach at least 1 foot (305 mm) below the usual
frost line.
It is recommended to caulk the base of the tank to prevent moisture and wind penetration.
In addition to the shut-off valve located inside the unit, we strongly recommend that a second, external shut-off
valve be installed outside of the concrete.
8
*Note that more than one thermal earth tube may be required.