Operating Instructions
For the Professional disinfection system,
check that the tub is empty (pilot light L1 on
the keyboard lights RED).
3) To start the disinfection cycle, press the
LYMPH DRAINAGE and CYCLICAL keys
simultaneously, holding them down for
about 3 seconds. The keyboard will begin
to fl ash and an acoustic signal will sound at
the beginning and at the end of the cycle to
warn the user that the disinfection cycle is
in operation.
N.B.: This starting procedure is designed to
act as a safety feature to prevent the user from
inadvertently starting the disinfection cycle.
Once the cycle has started, the tub returns
to standy-by mode and all the LEDs (with the
exception of LEDs L1 and L2) will switch off).
If the disinfection cycle does not start, check
that other functions have not been selected and
that the disinfectant tank contains disinfectant
(without which the disinfection cycle cannot be
started); if not, fi ll the tank and repeat the start-up
procedure from step 3.
Thatʼs all the information you need - you can
now step into the tub and enjoy the splendid
hydromassage that your Albatros tub can
provide.
How to operate the hydromassage system
6
The procedure described below shows the
sequence of operations required to use the
hydromassage system, and includes a few
useful tips.
Please remember that it is advisable to allow at
least two hours after a meal before enjoying a
relaxing massage.
First, switch the appliance on using the main
ON/OFF switch. Then fi ll the tub until the level
of the water is 5 - 6 cm above the hydromassage
Led 1
nozzles (LED L1 on the control keyboard must
be GREEN).
The ideal water temperature for an effective
hydromassage is very slightly above normal body
temperature, i.e. about 37°C.
The hydromassage system is factory-set for
a duration of 20 minutes. If desired, the cycle
can be repeated by pressing the WHIRLPOOL
key. However, a twenty-minute cycle is more
than suffi cient to ensure the full benefi ts of the
hydromassage system; it should be borne in
mind that longer hydromassage treatments may
lower the blood pressure or cause excessive
muscular relaxation.
Manuale Uso VS DIGIT - Code 10009716 - Edition 1 - 01/2006
At the end of the hydromassage cycle (if the
System Clean cycle is featured) check that all
the nozzles are open and exit the tub without
Led 1
draining the water (L1 lights GREEN); the water
can be used to clean the internal parts of the
hydromassage circuit using the disinfection cycle
(see instructions for the disinfection cycle).
The disinfection cycle lasts about two minutes,
and cannot be interrupted. At the end of the
disinfection cycle, open the drain outlet to empty
the tub.
If the tub features the Professional disinfection
system, open the drain outlet to empty the tub (L1
Led 1
lights RED) and start the cycle as described in
the instructions for the disinfection cycle. Check
that water mixed with disinfectant enters the tub
from all the nozzles; if one of the nozzles delivers
more water than the others, reduce the intensity
of the jet. In this case, too, the cycle is automatic
and lasts about two minutes. Once started, the
cycle cannot be interrupted.
At the end of the cycle, turn the main switch
to OFF.
It is advisable to sit or lie down for ten to twenty
minutes after a hydromassage in order to enjoy
the fullest effect.
Routine maintenance
7
Cleaning the Sanijet nozzles
In order to maintain perfect effi ciency, the nozzles
should be dismantled and cleaned at regular
intervals in order to remove any sediment or
scale.
Use the special wrench to rotate the nozzle
counter-clockwise until the internal ring can be
removed.
Extract the nozzle, dismantle and clean.
To replace the nozzle, perform the same
procedure in reverse.
Cleaning the suction nozzle
The suction nozzle features a special internal
device which prevents it from trapping hair and
other residue. This device should be checked
regularly in order to ensure complete effi ciency.
Using a cross-head screwdriver, remove the
screw and remove the fi lter plate from the nozzle.
Remove any residue by washing the parts with
water and a little bleach. Press the internal plate
gently with a fi nger and check that it moves
inwards by about 8 - 9 mm.
Replace the fi lter plate and the screw.