Special Cleaning Instructions; System Inspection - STA-RITE S7MD60 Manual Del Usuario

Filtros modulares de tierra de diatomeas
Ocultar thumbs Ver también para S7MD60:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Hazardous pressure.
Can cause severe
injury or major
property damage
from tank blow up.
Release all pressure
and read instructions
before working on filter.

Special Cleaning Instructions:

Use this procedure to clean scale or oils which are not removed by hosing
down module. Be sure to dispose of spent chemicals according to all applica-
ble codes and waste disposal ordinances. Use a soft stream nozzle to minimize
flying water and spray.
Risk of fire or explosion. Isolate filter from system before chemi-
cal cleaning; rinse filter and elements completely before returning to service.
If filter cannot be isolated, remove media and clean at another location. Follow
chemical manufacturer's instructions for use. Do not mix chemicals except as
directed by manufacturer. Do not allow cleaning chemicals to mix with or to
come in contact with chlorine, bromines, other chemicals, or chemical feed
devices.
1. Sponge or spray the module according to chemical manufacturer's directions.
2. If soaking is required, remove the module from the filter tank and sub-
merge it in a separate tank. Follow cleaner manufacturer's instructions
carefully.
3. After completing chemical manufacturer's instructions, drain and rinse the
module completely. Dispose of cleaners in accordance with local codes
and disposal ordinances.
4. Rinse the inside of the filter tank. Drain it completely.
5. Follow instructions in the "Assembly" and "Initial Startup" sections of this
manual.

SYSTEM INSPECTION

General:
Wash the outside of the filter with a mild detergent and water. Rinse off with a
hose.
NOTICE: DO NOT use solvents to clean the filter; solvents may damage plas-
tic components in the system.
NOTICE: Open the filter air release valve and release all air from the filter
each time the pump is stopped and restarted.
Weekly Inspection:
1. Remove debris from the pool skimmer basket.
2. Stop the pump; open the air release valve to release all pressure.
3. Remove the trap cover and basket; remove debris.
4. Check the pump for leaks. If found, see the pump owner's manual.
5. Replace the trap basket and the cover. Tighten the cover securely hand
tight. DO NOT use a lid wrench to tighten it.
6. Start the pump. When the filter air release valve runs a solid stream of
water, close the valve.
7. When the system has returned to normal operation, check the filter pres-
sure. If the filter pressure is 10 PSI (69kPa) or more higher than the initial
startup pressure, the filter needs cleaning. See "Cleaning the Filter", Page 9.