TROUBLESHOOTING
Fault phenomenon
Unfavorable
Sealing
Uneven sealing
The heating wire is broken
frequently
The heating blade is not rising
although the heating lamp is
bright
As the vacuum begins, the air is
not discharged from the bag
Cause analysis
The heating plate Teflon or silicon
foul
Teflon adhesive fabric damaged
Silicone gel damaged
Electric heating film damaged
Short cooling time
Silicone gel damaged
Long sealing time
Short cooling time
Tape damaged
Disabled electric heater
Electric heating film damaged
Heating transformer damaged
The gas nozzle is not in the bag
The vacuum is obstructed by the
bag
The gas nozzle and the filter are
dirty
Solution
Clean it with a cloth
Replace Teflon tape
Replace or clean
Replace heating film
Lengthen cooling time
Replace silicone gel
Adjust the time to the shortest
until it can be sealed
Lengthen cooling time
Replace the tape
Replace heater band
Replace heater band
Contact us or our agency,it is of
danger to replace by yourself
Turn off the power and restart it.
Get the goods close to the gas
nozzle
Clean the gas nozzle and the filter