Mark a point (3) on the horizontal line C, 130 (250 optional) mm to the right of the vertical
reference line.
Repeat this operation on the other side, checking that the two marks are on the same horizontal
line.
Fix the brackets (Optional):
Drill at the marked points (1) (2) (3), using a ɸ10 mm drill bit.
Insert the Wall Plugs 11 into the holes (1) (2) (3).
Fix the hood fixing bracket 20 with 3 screws 10 (5 x 50) supplied with the hood.
Fix a Chimney fixing bracket 21 with 2 screws 10 (5 x 50) supplied with the hood.
Hook the hood body:
Open the panel.
Remove the Metal grease filter using the handles provided.
Hook the hood body to the bracket 20.
Level the hood body itself.
From the inside of the hood body, fix the screws 10 to Wall Plugs 11 at the points (3).
Fit the filter into the hood.
Close the panel.
CONNECTIONS
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney
using either a flexible or rigid pipe ɸ 150 or ɸ 120 mm, the choice of
which is left to the installer.
To install a ɸ 120 mm air exhaust connection, insert the reducer
flange 3 on the hood body outlet.
Fix the pipe 4 in position using sufficient pipe clamps (not
supplied).
Remove possible charcoal filters.
Right
Wrong
EN-6