EN
Low battery warning
The LED light blinks once every three seconds. When connected
with a GSM or Wi-Fi control panel, the user will receive a text
message or App push notification for low battery warning. Please
replace the batteries as soon as you can.
Settings
Before the settings, remove the upper installation caps (marked
) and waterproof rubber plugs on both the transmitter and the
receiver, pull out both circuit boards gently and insert the batteries
(pay attention to the "+" and "-" polarity).
Power output setting
To set the output capacity, slide switch 1 of the power output
setting switch to adjust.
Factory default
High output setting
High output setting: ≥ 3m from the receiver
Low output setting: < 3m from the receiver
Low output setting
Zone mode setting
The zone mode types determine whether the control panel
receives the alarm and responds accordingly. The zone mode
setting can be adjusted by sliding switches 2 and 3 of the zone
mode and alarm time setting switch.
24-H zone (Factory default)
Normal zone
24-H zone: The IR sensors are in alert mode under all
circumstances. Upon detecting any intrusion, the control panel
immediately gives off an alarm.
It is best used for important areas that are usually not accessed.
Home mode zone: When the alarm system is armed, the IR
sensors are on guard. Upon detecting any intrusion, the control
panel immediately gives off an alarm. When the alarm system is
disarmed or home armed, the control panel will not give off an
alarm even the IR sensors are triggered.
It is best used for common areas where both family members and
intruders have access.
Normal zone: When the alarm system is armed or home armed,
the IR sensors are on guard, the control panel gives off an alarm
immediately as the sensors are triggered. When the alarm system
is disarmed, the control panel will not give off an alarm even the
sensors are triggered.
It is best used for areas where intruders may have access, but
family members have limited access.
EN
Home mode zone