Dehumidification Mode - Klarstein Mertrobreeze New York Smart 12K Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Dehumidification mode

• Select dehumidification mode by
pressing mode button or via remote
controller, and the dehumidification
indicator light is on.
• As shown in the picture below,
remove the plug of drainage outfall,
insert the aqueduct, and put another
end of the aqueduct into water
containers or drain channels.
When entering dehumidification mode, if the room temperature is ≥17°C (or 62°F), the
compressor will start to work. Then control according to the following rules: when room
temperature is ≤15°C, compressor stops; when the temperature rises back to ≥17°C
(59°F), the compressor restarts (the restart of compressor shall meet the 3-minute delay
protection function).
Note: When the dehumidification function is in use, the exhaust pipe assembly shall
be removed; otherwise it will lead to not obvious dehumidification effect or display
"FL" water full alarm.
Time mode
• In standby mode, press time button to set time start. Press the up-and-down button
to the time of start (0~24 hours), and time indicator light is on.
• In startup mode, press time button to set time switch-off.
• Press the up-and-down button to the time of switch-off (1~24 hours), and time
indicator light is on.
EN