Comfee MDDP-50DEN7 Manual De Instalación página 21

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
Removing the collected water
● Make sure the hose is secure so there are no leaks.
● Direct the hose toward the drain, making sure that there are no
kinks that will stop the warter flowing.
● Place the end of the hose into the drain and make sure the end
of the hose is level or down to let the water flow smoothly.Do
never let it up.
● Select the desired humidity setting and fan speed on the unit
for pump draining to start.
NOTE: The pump operation on light blinks at 1Hz when the
pump is operational failure. Please turn off the unit and plug
the power cord out. Check the following things:
● Cleaning the filter of the pump.
-Remove the bucket from the unit, take down the pump and
clean the filter of the pump (See Fig.12).
● Check that the pump drain hose does not link or block.
● Empty the water of the bucket.
● Reinstall the pump hose if it drops and reinstall the bucket
properly. Turn on the unit. If the error repeats, call for service.
NOTE: Do not operate pump function at or below 0°C (32°F),
otherwise water is become ice that will cause the water hose
blocked up and the unit failure. Make sure to empty the bucket
once a week when using the pump draining feature. When the
pump draining feature is not being used, remove the pump
drain hose from the outlet.
● Press the pump drain hose outlet in and take the pump drain
hose out from it (See Fig.13). Make sure do not let the water in
the pump hose drip to the floor.
Filter of the pump
2,Take the pump
drain hose out
19
OPERATING THE UNIT
Fig. 12
1,Press the pump drain hose
outlet in
Fig. 13

Hide quick links: