TROUBLE
Device will not turn on when
Power Button is pressed (no
audible hum of the Pump.)
Device turns on (audible hum
of pump heard) but will not
dispense.
Device turns on but only flows at
low pressure.
Hose Leaks at Tank connection.
Hose Leaks at Quick Connect.
Quick Connect Leaks.
Battery will not Charge.
TROUBLESHOOTING
LOOK FOR
1. Battery not charged. Light
does not turn ON.
2. Pump is damaged, over
heated, or non-functional. Visual-
ly inspect the Pump for damage.
Use the Charger to diagnose any
Battery problem. See Charging
the Pump Internal Battery.
3. Tank is already pressurized so
the Pump has turned off auto-
matically.
4. Pump is connected to Charger.
1. No liquid in Tank.
2. Quick Connect not secured to
equipment.
3. Pump is not tightened to Tank,
leaks at Seal.
1. Tank not yet pressurized.
2. Air leaking from Tank at Seal.
3. Tank Seal or Seal surfaces are
damaged.
4. Quick Connect not secured to
equipment.
1. Cracked, swollen or faulty
Hose.
2. Damaged connection.
1. Cracked, swollen or faulty
Hose.
2. Damaged connection.
1. Dirt or debris in Quick Connect.
2. Damaged O-Ring or Seal in
Quick Connect.
1. Charger not plugged into
outlet.
2. No Lights illuminated on
Pump. Charger plugged into
outlet.
3. No Lights illuminated on
Pump. Charger plugged into
outlet, outlet functioning.
4. Red Light continues flashing
on Pump (Battery temperature
too high for safe charging).
5. Red and Green Lights flash
alternately on Pump (Battery can-
not be charged).
REMEDY
1. Charge Pump if no Light is ON.
See Charging the Pump Internal
Battery.
2. Replace Pump if damaged or
non-functional. Allow Battery to
cool if overheated.
3. Open the Quick Connect to see
if water flows.
4. Disconnect Charger.
1. Add liquid to Tank. See Filling
the Sprayer.
2. Disconnect and reconnect
Quick Connect to equipment.
3. Tighten Pump to Tank.
1. Allow time for Pump to
pressurize Tank (at least to 20
seconds).
2. Tighten Pump to Tank.
3. Replace Tank Seal.
4. Disconnect and reconnect
Quick Connect to equipment.
1. Replace Hose Assembly.
2. Replace Quick Connect.
1. Replace Hose Assembly.
2. Replace Quick Connect.
1. Flush Quick Connect.
2. Replace Quick Connect.
1. Plug Charger into outlet.
2. Check that outlet is
functioning.
3. Replace Charger.
4. Allow Pump to cool.
5. Replace Pump.
Page 8