Fill Will Not Turn OFF

This is a troubleshooting flow chart for the K-1100, LX2, and LEV110CK/2G. Use it when the Fill function will not
turn off.
Is fill light
green or red?
Pull sensor out of water.
Disconnect blue valve
wires from control box.
Does green
fill light turn off?
Possible Issues:
1. Needs greased-filled
wire nut at valve.
2. Needs proper wire between
controller and valve: solid-
core 18-gauge wire with
poly-pro jacket.
3. Valve is bad.
Possible Issues:
1. Needs greased-filled wire nut at valve.
2. Needs proper wire between controller and valve:
solid-core 18-gauge wire with poly-pro jacket.
3. Valve is bad.
Jandy Levolor
®
Models K-1100, LX2, K-2300, and LEV110CK/2G
Fill Will Not Turn OFF
YES
Lockout sequence
has taken effect.
Call technical support at
1 800 822 7933.
Place sensor
back in water.
NO
Does sensor
light turn off?
YES
YES
Wait 20 seconds.
green fill light
YES
Electronic Water Leveler
NO
Is fill
light on?
NO
Does
turn off?
NO
PCB board
is bad.
|
Installation and Operation Manual
Possible Issues:
1. Manual lever on valve needs
to be turned off.
2. Valve is dirty: take valve
apart and clean inside.
3. Diaphram is torn.
4. LED light needs to be aligned
with lens cover.
Disconnect orange sensor
wires from control box
and touch them together.
Does
green fill light
turn off?
NO
YES
Sensor is bad.