ENGLISH
CAUTION
• The pulse oximeter is intended only as an adjunct in the patient assessment. It should be used when the patient presents clinical signs and
symptoms. The device is not intended to be used as a treatment.
• When using the pulse oximeter together with the electrical surgery equipment, the user must pay attention and ensure the safety of the patient.
• EXPLOSION HAZARD: Do not use the pulse oximeter in the presence of flammable anesthetics, explosive substances, vapors, or liquids.
• Make sure not to use the pulse oximeter during MRI (magnetic resonance imaging) scanning or CT (Computed Tomography) environment because
induced current could potentially cause burns.
• No modification of the pulse oximeter is allowed. Maintenance should be operated by a professional approved by the manufacturer.
• Please turn off the device before clean the pulse oximeter. Never allow high-pressure and high-temperature disinfection of the device. Never use
cleaning agents/disinfectants other than the recommended.
• The pulse oximeter is a sealed product. Keep its surface dry and clean, and prevent any liquid from infiltrating it.
• The pulse oximeter is accurate and fragile. Avoid pressure, knocking, strong vibration, or other mechanical damage. Hold it carefully and gently.
When it is not in use, it should be placed in a proper location.
• To dispose of the pulse oximeter and its accessories, follow local regulations or your hospital's policy regarding the disposal of such devices.
• Use AA alkaline batteries. Do not use carbon or poor quality batteries. Remove the batteries if the product will not be used for a long time.
• Please use the SpO2 sensor that corresponds to the product or use one that has been approved by the manufacturer. The user is responsible
for checking the compatibility of the pulse oximeter, the sensor, and the cable before use. Incompatible components may cause a degradation in
performance. If there are signs of damage, please stop use.
• The user should read the instruction manual carefully and ensure that it is understood or consult the manufacturer before use.
• Avoid static electricity. Before using the pulse oximeter, check the direct or indirect static electricity of all users and patients who will come into
contact with the device.
• If the pulse oximeter uses an unspecified and without EMC test system configuration, it can enhance electromagnetic radiation or reduce anti-
electromagnetic interference performance. Please use the specified configuration.
• Portable and mobile radio frequency communication equipment can affect the normal use of the pulse oximeter.
• The pulse oximeter should not be near or stacked with other equipment. If this situation occurs during use, check that it works normally with the
configuration you are applying.
• Never immerse or soak the pulse oximeter.
• Exercise caution during cleaning/disinfection to avoid wetting the socket.