Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Operating Instructions and Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain
the product described. Protect yourself and others by observing all safety information. Failure to comply with
instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Effluent Pump
Description
An effluent system consists of a pump,
control switch and a basin. The system
is generally controlled by a float switch
with a plug-in plug which accepts the
pump plug and in turn plugs into a 115
volt outlet.
The float switch is a wide angle
differential switch that rises with
the liquid level and turns the pump
on. As the liquid level decreases, the
float lowers and turns the pump
off. This pump is intended for use in
domestic sump or effluent lift stations.
It is suitable for pumping effluent,
wastewater, ground water and other
nonexplosive, noncorrosive liquids with
up to 3/4 inch solids.
Effl uent pump will
not pump raw
sewage or any substance exceeding
3/4 inch size.
Specifications
Power supply requirements .............. 115V, 60 hz
Circuit requirements .......................... 15 amps (min)
Motor duty ......................................... Intermittent
Motor ................................................. 115V, 1 Phase, 1725 RPM
Horsepower ....................................... 1/3
Motor full load .................................. 11 amps
Liquid temperature range ................. 40º F to 120º F
Max. operating position .................... 45º from vertical
Dimensions ......................................... 13-1/2 inch x 11 inch
Intake ................................................. 2 inch
Discharge ............................................ 2 inch NPT female, 3 inch
Cut-in level (factory set) .................... 18 inch
Cut-out level (factory set) ................. 10 inch
Differential ......................................... 8 inch
Switch ................................................. 90º wide angle
Power cord ......................................... 16 gauge 3 conductor
REMINDER: Keep your dated proof of purchase for warranty purposes!
© 2009 Blue Angel™ Pumps
Unpacking
Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return
the unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.
Safety Guidelines
This manual contains information
that is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
NPT male
mechanical tether switch
w/plug
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.blueangelpumps.com
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
information, that if not followed, may
cause damage to equipment.
General Safety Information
CALIFORNIA PROPOSITION 65
Danger indicates
chemicals known to the State of
an imminently
California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
Construction
Motor body material ............Cold rolled steel
Motor housing ......................Glass reinforced
Volute ....................................Glass reinforced ABS
Impeller .................................Glass reinforced PBT
Seal plate ..............................Cast Iron
Shaft seal ...............................End faced mechanical
Performance
GALLONS PER HOUR AT TOTAL HEAD IN FEET
Model
BEFL33
BEFL33-2
Model BEFL33, BEFL33-2
Warning indicates
a potentially
Caution indicates
a potentially
Notice indicates
important
This product or its
power cord contains
polypropylene
10
15
3600
1300
3600
1300
330103-002 3/09
200
0
0

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Blue Angel Pumps BEFL33

  • Página 1 Model BEFL33, BEFL33-2 Operating Instructions and Parts Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
  • Página 2 Operating Instructions and Parts Manual General Safety Information 6. Check hoses for weak and worn 11. This equipment is only for use on condition before each use, making 120 volt (single-phase) and is (Continued) certain that all connections are equipped with an ap proved 3-con- GENERAL SAFETY secure.
  • Página 3 Model BEFL33, BEFL33-2 General Safety Information valve in a horizontal position or at When a tether switch is used, rigid a 45º angle with the valve pivot on dis charge pipe is required. If the (Continued) top. In a vertical position, solids will...
  • Página 4: Troubleshooting Chart

    Operating Instructions and Parts Manual Maintenance (Continued) This pump contains dielectric motor 5. Submerge the complete pump in a oil for lubrication and motor heat disinfectant so lu tion (10% chlorine transfer. This oil can be harmful to the bleach solution) for at least one hour environment.
  • Página 5: Repair Parts List

    Model BEFL33, BEFL33-2 For replacement parts or technical assistance, call 1-888-636-6628 Please provide following information: Address parts correspondence to: - Model number Blue Angel Pumps - Serial number (if any) 101 Production Drive - Part description and number as shown in parts list Harrison, OH 45030 U.S.A.
  • Página 6: Service Record

    Operating Instructions and Parts Manual Service Record Date Maintenance performed Repair components required Limited Warranty For one year from the date of purchase, Blue Angel™ Pumps will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Blue Angel to be defective in materials or workmanship.
  • Página 7 Modèle BEFL33, BEFL33-2 Instructions d‘Utilisation et Manual de Pièces Veuillez lire et conserver ces instructions. Lire attentivement avant de commencer à assembler, installer, faire fonctionner ou entretenir l‘appareil décrit. Protégez-vous et les autres en observant toutes les informations sur la sécurité.
  • Página 8 Instructions d‘Utilisation et Manual de Pièces Généralités Sur La Sécurité 6. Inspecter les tuyaux pour la faiblesse 11. Cet équipement est conçu pour un et l’usure avant chaque utilisation circuit de 120 v (monophasé) et est (Suite) et vérifier le serrage de tous les équipé...
  • Página 9 Modèle BEFL33, BEFL33-2 Généralités Sur La Sécurité Installation Avant d’enlever la pompe du bassin (Suite) Utiliser un/des pour l’entretien, toujours couper système(s) de Le moteur de la puissance à la pompe et à sauvegarde là où il y a risque de la pompe est l’interrupteur de commande.
  • Página 10: Guide De Dépannage

    Instructions d‘Utilisation et Manual de Pièces Entretien (Suite) montage incorrect peuvent résulter au nettoyage. en hasard de secousse électrique. Enlever le couvercle du bassin Netttoyer toute saleté et dépots de et débrancher la tuyauterie de Situer la pompe dans un endroit l’arrivée de la pompe et la volute.
  • Página 11: Guide De Dépannage (Suite)

    Modèle BEFL33, BEFL33-2 Guide de Dépannage (Suite) Symptôme Cause(s) Possible(s) Mesure Corrective La pompe 4. Pompe fonctionne à l’envers 4. Vérifier la rotation. (sens contraire des aiguilles d’une montre du bas) fonctionne mais Retourner si au sens des aiguilles d’une montre délivre peu ou...
  • Página 12: Garantie Limitée

    Instructions d‘Utilisation et Manual de Pièces Enregistrement d’entretien Date Entretien exécuté Éléments de remplacement requis Garantie Limitée Pour un an à compter de la date d’achat, Blue Angel™ Pumps vas réparer ou remplacer, à son option, pour l’acheteur originel n’importe quelle pièce ou pièces de ces Pompes (“Produit”) déterminées défectueuses, par Blue Angel, en matière ou en fabrication.
  • Página 13 Modelo BEFL33, BEFL33-2 Manual de Instrucciones de Operación y Piezas Por favor lea y guarde estas instrucciones. Léalas cuidadosamente antes de tratar de montar, instalar, operar o dar mantenimiento al producto aquí descrito. Protéjase usted mismo y a los demás observando toda la información de seguridad.
  • Página 14 Manual de Instrucciones de Operación y Piezas Informaciones Generales de Antes de cada uso, inspeccione ¡Peligro las mangueras, para ver si están Seguridad (Continuación) de choque eléctrico! Nunca dañadas o desgastados y cerciórese conecte los cables verdes o GENERALES DE SEGURIDAD de que las conexiones estén bien verde con rayas amarillas, a apretadas.
  • Página 15: Instalación

    Modelo BEFL33, BEFL33-2 Informaciones Generales de Enrosque la tubería de descarga o M antenimiento el niple en el orifi cio de descarga Seguridad (Continuación) Siempre desconecte de la unidad. 13. Es altamente recomendable que el cordón eléctrico Si usa una válvula de chequeo, en...
  • Página 16: Guía De Diagnóstico De Averías

    Manual de Instrucciones de Operación y Piezas M antenimiento Coloque la bomba en un Limpie bien el orificio de entrada de sitio adecuado para limpiarla la bomba y la voluta. (Continuación) completamente. Quítele todos los Esta bomba Chequée la bomba periódicamente residuos e impurezas a la bomba.
  • Página 17: Lista De Partes De Reparación

    Modelo BEFL33, BEFL33-2 Guía de diagnóstico de averías (Continuación) Symptôme Cause(s) Possible(s) Mesure Corrective La bomba 4. La bomba está rotando en sentido 4. Chequée la rotación. (Sentido contrario al de las agujas del reloj al observarlo desde funciona pero...
  • Página 18: Registro De Servicios

    Manual de Instrucciones de Operación y Piezas Registro de Servicios Fecha Maintenimiento efectuado Componentes de reparación necesarios Garantía Limitada Durante un año a partir de la fecha de compra, Blue Angel reparará o reemplazará, según lo consideren adecuadon, cualquier pieza de esta bomba para sumideros (“Producto”) que el comprador original envie a reparación y los empleados o representantes autorizados de Blue Angel determinen que están defectuosos debido a problemas de materiales o manufactura.
  • Página 19 BEFL33, BEFL33-2 Notes / Notas / Notes...
  • Página 20 Operating Instructions and Parts Manual • Instructions d‘Utilisation et Manual de Pièces • Manual de Instrucciones de Operación y Piezas Notes / Notas / Notes...

Este manual también es adecuado para:

Befl33-2

Tabla de contenido