Firmware; Sessions - Ingeteam INGEREV GARAGE Basic Manual De Configuración

Ocultar thumbs Ver también para INGEREV GARAGE Basic:

Publicidad

Idiomas disponibles

Idiomas disponibles

Folder system
start_deferred_charge
Enables the start time of the deferred charge to be programmed. This variable is disabled by default.
To program the start of the deferred charge, a user.ini file must be uploaded with a variable that has a valid time
programmed.
The format of the variable is 24 hours, set as follows hh:mm:ss.
Example:
start_deferred_charge = "23:05:00";
To disable the end of the deferred charge a user.ini file must be uploaded containing an empty variable.
Example:
start_deferred_charge = "";
finish_deferred_charge
Enables the end time of the deferred charge program to be programmed. This variable is disabled by default.
To program the end of the deferred charge a user.ini file must be uploaded with a variable that has a valid time
programmed.
The format of the variable is 24 hours, set as follows hh:mm:ss.
Example:
finish_deferred_charge = "09:55:00";
To disable the end of the deferred charge a user.ini file must be loaded containing an empty variable.
Example:
finish_deferred_charge = "";

4.3. Firmware

The device firmware must go in this folder if an update is necessary.
The extension of the firmware filename is .bin.

4.4. Sessions

This folder houses the file that contains all the information relating to the charging sessions of the device and the
important warnings, alarms and events that have taken place.
If the unit has an energy meter, the stored information will include the consumption rates of each session.
Otherwise, only information on the duration of the sessions will be available.
The file format is plain text in csv format so that it can easily be imported from a spreadsheet application or other
data treatment systems.
If the file does not exist, a new one is generated.
If the file already exists, the new information is added to it without deleting the existing information.
ABA2021IQM05_A - Configuration
Power reference table as per phases, voltage and current
Three phase
400V 6 A
400V 8 A
400V 10 A
400V 12 A
400V 16 A
400V 20 A
400V 24 A
400V 28 A
400V 32 A
4.15 kW
5.54 kW
6.92 kW
8.31 kW
11.08 kW
13.85 kW
16.62 kW
19.39 kW
22.17 kW
Ingeteam
EN
ES
FR
IT
11