OPERaTING INsTRUCTIONs (CONTINUED)
Digital Timer Function Modes
ON -- OFF Loop Mode: Timer begins ON/OFF cycle in ON state.
OFF -- ON Loop Mode: Timer begins ON/OFF cycle in OFF state.
ON Mode: Non-cycling (manual mode). Timer is ON for specified time
before switching to STOP setting (display "- - .- - .- -''). Press RESET
to restart ON mode.

Changing settings

When settings are being changed the device will pause function until new
conditions are set or setting mode is exited.
Factory Default Settings: ON -- OFF loop mode; ON state with 2 seconds
countdown, OFF state with 2 seconds countdown.
To modify the function mode and time, press MODE button which
shows "ON - OFF".
Pressing Mode again switches between Operation Modes. Press
ENTER to select desired mode and set the timer. Passing through all
three modes will reset device and timer will continue operating under
old conditions.
Selecting "ON -- OFF" will have ON timer first. Selecting "OFF -- ON"
will have OFF timer first. Selecting "ON" will only have ON timer to set.
Press the ADD button to increase the time, press ENTER to confirm
the number and move on to the next digit. Once the 6th digit is set,
unit enters the next timer setting (unless ON mode was selected).
Repeat the process.
After timers are set, display will flash the function mode four times
and device will begin operating under the new conditions.
Reset function: press the RESET button. The system will stop the
current parameters and start the cycle work from the beginning
according to the parameters which have been set.
9