112
Indication of print speed in mm/s.
The print speed can be determined for each print order anew. The setting of print speed affects
also the test prints.
Value range: 50 mm/s ... 300 mm/s (see the technical data).
Indication of value to set the print intensity when using different materials, print speeds or printing
contents.
Value range: 10 % ... 200 %.
Examination if the transfer ribbon roll is to end or if the ribbon was torn at the unwinding roll.
Off: The ribbon control is deselected, i.e. the printer continues without an error message.
On, weak sensibility: The current print order is interrupted and an error message appears at the
display of the printing system. The printing system reacts at approx. 1/3 more slowly to the end of
the transfer ribbon (default).
On, strong sensibility: The current print order is interrupted and an error message appears at
the display of the printing system. The printing system reacts immediately to the end of the
transfer ribbon.
Indication of initial point displacement in mm.
Displacement of the complete print in paper direction. With positive values the print in paper
direction starts later.
Value range: −30.0 ... +90.0.
Displacement of the complete print transverse to the paper direction.
The displacement is possible only up to the edges of the printing zone and is determined by the
width of the focal line in printhead.
Value range: −90.0 ... +90.0.
Indication of value to which the last label of a print order is moved forward and is moved back to
the beginning of label at a new print start.
Value range: 0 ... 50.0 mm
Standard: 12 mm.
Indication of label length in mm.
Minimum height: 15 mm
Indication of distance between two labels in mm.
Minimum value: 1 mm.
Indication of width of one label as well as how many labels are placed side by side.
Press key
to start measuring.
Generally adhesive labels are set. Press key
to select continuous labels.