NOTICE
We encourage the use of authorized Allmand
parts. The warranty does not cover damage or performance
problems caused by the use of parts that are not authorized
replacement parts.
1. Check that a copy of the Operator's Manual is with the
unit.
2. Check that all safety decals are legible and in place on
the unit. See Safety Decals in the Safety section of
this manual.
3. Check the unit for proper operation. (See Operating The
Unit for detailed information on operating procedures.)
• Check that the inner mast extends and retracts
properly, and that inner mast can be locked in each
height position with the latch spring pin.
• Check that the LED fixture hardware is tightened.
• Check that the power cord, base cable and fixture
cable are not frayed or damaged, and that the
connectors are not damaged.
• Check that the mast socket knob securing the outer
mast to the base assembly is tightened.
• Check the condition of the wheels, and that they roll
freely.
4. Plug the power cord into a wall outlet or power generator.
See Specifications for detailed information on power
requirements.
5. Turn the power switch to the ON position to check the
LED fixture. See Troubleshooting if the LED fixture
does not light. When finished, set the power switch to the
OFF position and disconnect the power cord from the wall
outlet or power generator.
Work Site Considerations
Prior to setting up and operating the work light, the operator
must determine where to place it on the work site. It is the
operator's responsibility to ensure that the work light is
properly and safely positioned on at the work site. Be sure to
follow rules or instructions for your work site, and any state,
province and federal rules that may apply.
®
replacement
Overhead Obstructions
Always keep well clear of any overhead power wires. Make
sure there are no overhead obstructions where you intend to
place the portable work light. Keep clear of any loose cables,
ropes or obstructions that could ensnare the mast or LED
fixture. When the mast is fully elevated, the portable work
light stands 9.6 feet (2.9 m) from ground level to the top of the
LED fixture.
DANGER
Electrocution Hazard.
Contact with overhead electrical wires will result in death
or serious injury. Always follow the rules or instructions for
your work site, and the state, province and federal rules for
maintaining a safe distance from overhead wires.
Wetness & Wind
The portable work light must be placed on a dry surface away
from areas that might become wet.
WARNING
Shock Hazard.
Positioning a portable work light on a wet surface or in
water will result in death or serious injury. Always position
the work light on a dry surface away from areas where
water may flow or accumulate.
Do not set up the work light in an area where winds exceed
10 mph (16 km/h).
WARNING
Unsafe Operation Hazard.
Operating the portable work light with the mast fully
elevated in winds exceeding 10 mph (16 km/h) can cause
work light tip over resulting in death or serious injury.
Always fully lower the mast when winds are expected to
exceed 10 mph (16 km/h).
7