LED indications and checks: the LED switching on confirms every alarm. The LED
flashing after an alarm means "low battery".
Radio transmissions: digital in contemporaneous double frequency Dual Band, factory
coded and managed through self learning from microprocessor - features and power
according to law - radio emission range covered: 100m in open air and in total absence
of radio noises on the bands. The same may sensibly decrease indoors, depending on
the position of the devices with regard to the structure of the rooms and/or presence of
radio noises on the bands. Before making final installation, make sure that the radio
ranges are sufficient.
Dip switches E: please programme before feeding the equipment - to modify,
take the battery out, change the dip-switches and re-programme the sensor.
1 ON
= radio transmission for opening (alarm) and closing reed/NC contact,
to obtain a "open door" warning from panel.
1 OFF
= alarm transmission only
2 ON
= 2 different encoded transmission for reed alarm or NC/NO input onboard
2 OFF
= the same code is transmitted for both alarms.
3 ON
= activation of pulses counting (6 = alarm) for the terminal board NC input
3 OFF
= NC opening input or NO closing input alarm
4 ON
= engage break sensor, the alarm contemporarily with the magnet
moving away
4 OFF
= disengage break sensor.
NOTE : when setting is 1 ON - 2 ON - 3 OFF there will be an alarm/end alarm
transmission for both events. When setting is 1 ON - 2 ON - 3 ON there will be no end
alarm transmission on the NC input as it is programmed for fast sensors.
INSTALLATION – follow the operations sequence
• Fasten the Sensor to the fixed part and the magnet to the mobile part of the frame,
using the best suitable of the two supports as shown in the drawings.
• Set dip-switch 1,3,4 as requested by the installation; leave dip switch 2 on OFF.
• Set the control panel to programming the sensor. By inserting the battery inside the
device a BEEP from the panel confirms the correct programming.
• In case you use the terminal board and you want to have two different alarms, set the
control panel to receive a second code, then switch ON the dip switch 2: the control
panel confirms.correct programming.