EN
INSTRUCTIONS FOR USE
MAINTENANCE
The hydraulic system (pump/cylinder) is a sealed system, that requires only a monthly oiling of the moving parts.
In case the hydraulic unit leaks
oil or has to be dismantled for gaskets replacement, you need to make the pump working and slowly add oil
throught the filling hole. When the
transmission jack is in the lowest position, the oil level should not exceed the filling cap level. For dismantling
apply to authorized people.
Required quantity of oil: 0,95 lt.
The hydraulic system contain enough oil when the jack reaches the highest position.
WARNING
a surplus of oil might cause troubles.
Usable oil: any hydraulic oil of gradation ISO 22 (ref. Shell Tellus oil 22 or equivalent) . NEVER USE BRAKE
FLUID.
Oil the pedal mechanical parts every 2 months with an higth quality oil and grease the head pumping element. In
case of oil leaking from the hydraulic system replace the seals.
INSPECTIONS
● Before using, each jack should be checked to exclude leaks, damages, missing, loose and worn parts.
● Each jack shall be inspected immediately if it is believed to have been subjected to an abnormal load or shock.
IT IS RECOMMENDED that this inspection be made by supplier's skilled personnel It is recommended that
an annual inspection of the jack be made by a supplier's authorized specialist and that defective and dangerous
parts must be replaced with original spare parts supplied by the manufacturer (see spare parts list).
DAMAGED JACKS
Every damaged, very used or abnormally operating jack SHALL BE REMOVED FROM SERVICE..
JACKS DESTRUCTION
When the jack must be destructed, materials must be recycled according to the country law in force.
EC Declaration of Conformity:
BETA UTENSILI S.p.A. hereby declares that pit jack 3026 complies with "Machine Directive" 2006/42/EC
MASSIMO CICERI
( Member of the board)