2.

Malfunction

Anomalies
The machine does not turn on.
The machine is on, but there is no motion.
The self-centering chuck does not rotate in any direction.
The self-centering chuck turns with insufficient strength.
The machine (self-centering chuck and bead break-
er arm) makes no hydraulic motion.
Robert Bosch GmbH
Malfunction | TCE 4510 | 19
Causes and possible solutions
Check the electrical supply, the plug, the so-
+
cket, the fuses on the plug.
+
Check the fuses in the electrical panel.
+
Check the correct rotation of the hydraulic pump, if ne-
cessary reverse rotation direction (see chap. 3).
+
Control joystick defective, replace (see chap. 3).
+
Electrovalve blocked, try to unblock manu-
ally or replace the component (see chap. 3).
+
Low tension fuse is burnt, replace.
+
Check the correct insertion of the plug and its connection.
+
Turn on the main switch.
+
Pedal inverter defective, replace.
Check the correspondence of the mains tension
+
+
with that shown on the registration plate.
+
Adjust the belt tightener (see instructions).
+
Check the tension on the three phases (N.B.:
the neutral cable is never used).
Wrong rotation direction of the hydraulic pump, in-
+
vert the phases in the tension plug.
+
Motor protector activated, turn on again the
thermal-magnetic circuit breaker.
Lack of oil in the circuit, top up.
+