6. Pass the motor lead wire through the slot of the hanger rod, and
tighten the motor assembly to the hanger rod with (H8)
M14x100mm screw, (H9) M12x90mm screw, (H13) 14mm flat
washer, (H21) 14mm self-tapping nut and (H22) 12mm
self-tapping nut.
Motor Lead
Wire
H8
H9
7.Pass the (H2) safety steel cable through the motor safety hole,
encircle one end of cable , and attach the (H4) steel cable lock
onto the cable for secure installation.
Pull the other end of the steel cable into the center hole of the
hanger rod and out through the hanger rod , encircle the cable
around the I-beam, and then attach the (H4) steel cable lock
onto the cable for secure installation.
H4
Motor Safety
Hole
HVLS BLDC Fan
8.Install the fan blade cap and fan blade cap spacer to the fan
blade with (H12) M6x35mm screw , (H16) 6mm flat washer and
(H24) 6mm self-tapping nut. Repeat this step for all 6 fan blades.
H13
H16
H21
H22
9. Install all the fan blade assembly to the fan blade holder. Then
place the fan blade safety gasket (10) onto the fan blade side by
side, align the screw holes and tighten with (H11) M8x45mm
screws, (H15) 8mm flat washer and (H23) 8mm self-tapping nut.
H2
H4
8
H24
H12
H23
H15
H11
User's Manual
12
9
10