Electrical Wiring - Global Industrial HVLS BLDC 293042 Instrucciones De Ensamblaje

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

User's Manual
10. Rotate the motor cap (11) to the fan assembly until tighten.

ELECTRICAL WIRING

1. Open the junction box cover on the hanger rod, and connect
the motor lead wire and 4x16AWG interconnecting cord to the
terminal as shown below, make sure tighten all the terminal
screws.
Junction Box
Motor Lead
Wire
U
V
W
G
HVLS BLDC Fan
11
U
U
V
V
W
W
G
G
4x16AWG
Interconnecting
Cord
11.Install the (H25) plastic anchor to the wall at the distance
shown as below. Then install the control box to the plastic anchor
with (H26) M6x60mm screw.
Warning: Do not install closer than 1 foot (0.3 m) from both sides
of the control box to any adjacent surface/wall.
H26
2.Open the control box wiring cover, and connect the fire alarm
wire, 4x16AWG interconnecting cord and power-supply
conductor as shown below.
OVERLOAD
OFF
PROTECTION
REV
FWD
PRESS TO
ON
RESET
SPEED
Connect the lead wire of the fire alarm
to the terminal 1, and then connect the
4x16AWG interconnecting cord and the
power-supply conductor to the terminal
2 as below picture.
_
+
FIRE
- +
Lead Wire of
Power-Supply
Fire Alarm
Conductor
9
H25
OVERLOAD
OFF
PROTECTION
REV
PRESS TO
FWD
ON
RESET
SPEED
_
+
G L1 L2
G
U V W
POWER
MOTOR
FIRE
- +
G
L1L2
G
U
V W
FIRE
ALARM
G L1 L2
G
U V W
POWER
MOTOR
G L1L2
G
U V W
4x16AWG
Interconnecting Cord

Publicidad

Tabla de contenido

Solución de problemas

loading