Descargar Imprimir esta página

Urmet Yokis MTM2000E Guia De Inicio Rapido página 3

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 4
MTM2000 - 2000W STAIRCASE LIGHT TIMER
MTM2000E
5454351
MTM2000M
5454361 2000W DIN Rail Staircase Light Timer
Functions
The timer may be used with one or more pushbuttons. Versions for
flush-mounted or DIN rail installation are available. Wiring and
functions are identical in all cases.
Pushbutton anti-jamming function with accessory R1500 (cod.
5454074).
Can also function with pushbutton with indicator lamp, both in timer
mode (default) or in relay mode.
IMPORTANT:
Before starting any configuration, short press 23 times to unlock the relay. The module will lock again automatically after 6
hours. It can be blocked immediately by using a 21 short presses sequence.
TIMINg
Time configuration: The preset timing is 2 minutes. All configurations are stored in the case of blackout. The switch-on
time can be configured from 2 seconds to 4 hours by means of short presses sequences (see table). Press 25 times to set
the time in seconds (from 2 seconds to 4 minutes): (reply: 5 flashes). Short press 26 times to go back to timing in minutes
from 2 minutes to 4 hours): (reply: 6 flashes).
Extended time: "Extended time" is off by default. Short press 29 times to activate the "extended time" function. The light
will be switched on for 12 hours when a connected pushbutton is held pressed for longer than 3 seconds. Press once to
switch it off before the time. The module will resume normal operation after switch-off (with the set time).
Warning: Warning is off by default. Short press 24 times to activate the warning function. The light will flash briefly one
minute before the switch-on time expires (10 seconds if the time was programmed in seconds). The pushbutton can be
pressed again before the light goes out to extend the switch-on time.
ANTI-jAMMINg FUNCTION
This function is not active by default. The anti-jamming function may be used in common areas to ensure that the light
switches off even if a pushbutton remains jammed. To do this, equip each pushbutton with a small R1500 accessory (Code
5454074) connected in series to the pushbutton (see wiring diagram).
Short press 20 times to activate the anti-jamming action.
MODULE CONFIGURATION TABLE
------ time configuration -------
Number of
Time (4)
presses (1)
11
2 minutes
12
4 minutes
13
8 minutes
14
15 minutes
15
30 minutes
16
60 minutes (1 hour)
17
120 minutes (2 hours)
18
240 minutes (4 hours)
19
no timing
(1) Short presses sequence on pushbutton.
(2) Confirmation reply with flashes or relay clicks at end of presses sequence.
(3) To switch the function on and off alternatively (activation and deactivation switch)
(4) The time may be set in minutes (default) or in seconds.
Customer Service: +39 011.23.39.810 - Export Dept. Phone: +39 011.24.00.250/256 -
WARRANTY: In addition to the warranty required by law, this product is guaranteed for 5 years from date of manufacture. The material must be used according to the instructions
provided and for its intended use. Faults must not be caused by deterioration or accidents resulting from negligence, anomalous use or incorrect installation. In all cases, the warranty
only includes replacement of faulty products. No compensation for loss or damage may be claimed.
DS1054-007C
2000W Flush-mounted Staircase Light
Timer
Reply (2)
1 flash
2 flashes
3 flashes
4 flashes
5 flashes
6 flashes
7 flashes
8 flashes
9 flashes
Urmet S.p.a. – 10154 TORINO (ITALY) – Via Bologna 188/C
For technical information, go to www.yokis.com or call:
Fax: +39 011.24.00.296
Technical specifications
Mains voltage:
MTM2000E
Power on resistive load 10A - 250 VAC Max. 2500VA
Power on other loads
MTM2000M
Power on resistive load 10A - 250 VAC Max. 2500VA
Power on other loads
Module consumption:
Sound level:
Ambient temperature:
Electronic coil:
Maximum current of all pushbutton warning lights:
------ function configuration -------
Number of
Function
presses (1)
20
Anti-jamming mode (3)
21
Lock configurations
22
-
23
Unlock configurations
24
Enable switch-off warning (3)
25
Set time in seconds (4)
26
Set time in minutes (4)
27
Relay/timer mode (3)
29
Enable extended time (3)
30
Full reset to default settings
32
Compatibility with CVI34
P3
gB
230V +/- 15% - 50Hz
3A - 250 VAC Max. 500VA
5A - 250 VAC Max. 750VA
< 1W
< 60dB at 20cm
from -20°C to +60℃
230 VAC
20mA (equal to approximately 20 pushbuttons)
Reply (2)
10 flashes
1 flash
3 flashes
4 flashes
5 flashes
6 flashes
7 flashes
9 flashes
2 flashes
2 flashes

Publicidad

loading

Este manual también es adecuado para:

Yokis mtm2000m54543515454361