Solar Power Inverter Safety Features - Solar PI15000X Manual De Instrucciones

Ocultar thumbs Ver también para PI15000X:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4. Coil the television power cord and the power cables running from the 12 Volt
power source to the power inverter.
5. Attach a "Ferrite Data Line Filter", available at most electronic supply stores, to
the television/audio device power cord. More than one filter may be required.

SOLAR Power Inverter Safety Features

Your SOLAR power inverter is equipped with automatic shut off protection which will
be activated if any of several unsafe operating conditions exist. In the event that any
of the following conditions occurs, the Red LED Indicator light will turn on and the
power inverter will shut down:
1. The power input from the 12 Volt power source drops to 9.5 Volts. (When the
power from the 12 Volt power source drops to 10.5 Volts, an extended audible
alarm will sounds, warning you that your power source is low.)
2. The power input from the 12 Volt power source exceeds 15.5 Volts.
3. The "continuous power" demand from the powered device exceeds the
continuous power rating of your power inverter.
4. The "peak power" demand from the powered device exceeds the peak power
rating of your power inverter.
5. The circuit temperature within the power inverter exceeds 165˚F.
Note: Your power inverter is equipped with a cooling fan, which is designed to
run continuously when the inverter is in use. Automatic shut down caused by
high circuit temperature will occur when the cooling fan is unable to maintain a
cool enough temperature for safe operation of the power inverter.
In the event the automatic shut down protection occurs or the inverter sounds a
continuous audible alarm, turn
power inverter until the source of the problem has been identified and corrected.
SOLAR Power Inverter Maintenance – Replacing Blown fuses
Your SOLAR power inverter is equipped with fuses of specific amperage rating and
physical design. In most cases, the fuses should not need to be replaced. In the event
they may be needed, replacement fuses are included with your power inverter. If you
require additional fuses over and above those provided with your product, it is
important that you purchase and install the correct replacement fuse(s). Please
reference the chart below to determine the correct fuse(s) for your product.
Model No.
PI15000X
PI4000X
PI8000X
PI12000X
PI24000X
SOLAR Power Inverter USER'S MANUAL
the power inverter immediately. Do not re-start the
OFF
No. of Fuses
1
1
3
4
8
Fuse Rating
15 Amp
40 Amp
35 Amp
35 Amp
35 Amp
Fuse Type
Spade Type
Spade Type
Spade Type
Spade Type
Spade Type